5-3
5-2 REFERENCE
ADJUSTMENT
• Touch [REF] on the main menu screen.
NOTE: DO NOT
change the test equipment output level until the second beeps sound.
ADJUSTMENT
ADJUSTMENT ITEM DISPLAY
CONDITION
OPERATION
PREPARATION
1 –
–
Touch [REF] to start
the reference frequency
adjustment.
REFERENCE
FREQUENCY
2 REF OSC
• Connect the test equipment to the
[ANT1], and set as shown below:
Frequency: 250.0
MHz
Modulation: None
Level: +40
dB
μ
†
(–67 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound
after the adjustment is
completed.)
PLL UNLOCK
3 REFULK ck
4 PULK0 ck
5 PULK1 ck
6 PULK2 ck
• After the adjustment, the receiver shows the reference adjustment menu.
• Push [EXIT] to return to the main menu screen.
5-3
HF RECEIVE ADJUSTMENT
• Touch [HF-RX] on the main menu screen.
NOTE: DO NOT
change the test equipment output level until the second beeps sound.
ADJUSTMENT
ADJUSTMENT ITEM DISPLAY
CONDITION
OPERATION
PREPARATION
1 –
–
Touch [HF-G] to start the
HF total gain adjustment.
HF TOTAL GAIN
(Preamp OFF)
2 HF Total Gain PRE OFF ref
• Connect the test equipment to the
[ANT1], and set as shown below:
Frequency: 14.1515
MHz
Modulation: None
Level: +60
dB
μ
†
(–47 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound
after the adjustment is
completed.)
3 HF Total Gain PRE OFF set
• Set the test equipment level to:
Level: OFF
Touch [SET].
(A beep sounds, and then
another beeps sound 10
seconds later.)
HF TOTAL GAIN
(Preamp ON)
4 HF Total Gain PRE ON ref
• Set the test equipment level to:
Level: +60
dB
μ
†
(–47 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound
after the adjustment is
completed.)
5 HF Total Gain PRE ON set
• Set the test equipment level to:
Level: OFF
Touch [SET].
(A beep sounds, and then
another beeps sound 10
seconds later.)
HF S-METER
6 HF S0 LEVEL
• Set the test equipment level to:
Level: +4
dB
μ
†
(–103 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound 1
second later.)
7 HF S9 LEVEL
• Set the test equipment level to:
Level: +34
dB
μ
†
(–73 dBm)
8 HF S9+60 LEVEL
• Set the test equipment level to:
Level: +94
dB
μ
†
(–13 dBm)
9 HF dBu –10dBu
• Set the test equipment level to:
Level: –10
dB
μ
†
(–117 dBm)
10 HF dBu 0dBu
• Set the test equipment level to:
Level: 0
dB
μ
†
(–107 dBm)
11 HF dBu 10dBu
• Set the test equipment level to:
Level: +10
dB
μ
†
(–97 dBm)
12 HF dBu 20dB
• Set the test equipment level to:
Level: +20
dB
μ
†
(–87 dBm)
13 HF dBu 40dBu
• Set the test equipment level to:
Level: +40
dB
μ
†
(–67 dBm)
14 HF dBu 60dBu
• Set the test equipment level to:
Level: +60
dB
μ
†
(–47 dBm)
15 HF dBu 80dBu
• Set the test equipment level to:
Level: +80
dB
μ
†
(–27 dBm)
†
: The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.
Содержание IC-R8600
Страница 1: ...S 15404XZ C1 June 2017 SERVICE MANUAL COMMUNICATIONS RECEIVER iR8600...
Страница 9: ...3 2 FRONT UNIT DIM CTRL Q43 DIM CTRL Q41 TW CTRL IC52 D A CONVERTER IC102 BUFF IC103 FRONT CPU IC101...
Страница 84: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan S 15404XZ C1 2017 Icom Inc...