5-5
5-4
VU RECEIVE ADJUSTMENT
• Touch [VU-RX] on the main menu screen.
NOTE: DO NOT
change the test equipment output level until the second beeps sound.
ADJUSTMENT
ADJUSTMENT ITEM DISPLAY
CONDITION
OPERATION
PREPARATION
1 –
–
Touch [VU1] to start
the VU-1 total gain
adjustment.
VU1 TOTAL GAIN
(Preamp OFF)
2 VU1 Total Gain PRE OFF ref
• Connect the test equipment to the
[ANT1], and set as shown below:
Frequency: 50.1515
MHz
Modulation: None
Level: +60
dB
μ
†
(–47 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound
after the adjustment is
completed.)
3 VU1 Total Gain PRE OFF set
• Set the test equipment level to:
Level: OFF
Touch [SET].
(A beep sounds, and then
another beeps sound 10
seconds later.)
VU1 TOTAL GAIN
(Preamp ON)
4 VU1 Total Gain PRE ON ref
• Set the test equipment level to:
Level: +60
dB
μ
†
(–47 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound
after the adjustment is
completed.)
5 VU1 Total Gain PRE ON set
• Set the test equipment level to:
Level: OFF
Touch [SET].
(A beep sounds, and then
another beeps sound 10
seconds later.)
VU1 S-METER
6 VU1 S0 LEVEL
• Set the test equipment level to:
Frequency: 50.1515
MHz
Modulation: None
Level: 0
dB
μ
†
(–107 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound 1
second later.)
7 VU1 S9 LEVEL
• Set the test equipment level to:
Level: +34
dB
μ
†
(–73 dBm)
8 VU1 S9+60 LEVEL
• Set the test equipment level to:
Level: +94
dB
μ
†
(–13 dBm)
9 VU1 dBu –10dB
• Set the test equipment level to:
Level: –10
dB
μ
†
(–117 dBm)
10 VU1 dBu 0dB
• Set the test equipment level to:
Level: 0
dB
μ
†
(–107 dBm)
11 VU1 dBu 10dB
• Set the test equipment level to:
Level: +10
dB
μ
†
(–97 dBm)
12 VU1 dBu 20dB
• Set the test equipment level to:
Level: +20
dB
μ
†
(–87 dBm)
13 VU1 dBu 40dB
• Set the test equipment level to:
Level: +40
dB
μ
†
(–67 dBm)
14 VU1 dBu 60dB
• Set the test equipment level to:
Level: +60
dB
μ
†
(–47 dBm)
15 VU1 dBu 80dB
• Set the test equipment level to:
Level: +80
dB
μ
†
(–27 dBm)
VU2 TOTAL GAIN
(Preamp OFF)
16 VU2 Total Gain PRE OFF ref
• Set the test equipment to:
Frequency: 625.0215
MHz
Modulation: None
Level: +60
dB
μ
†
(–47 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound
after the adjustment is
completed.)
17 VU2 Total Gain PRE OFF set
• Set the test equipment level to:
Level: OFF
Touch [SET].
(A beep sounds, and then
another beeps sound 10
seconds later.)
VU2 TOTAL GAIN
(Preamp ON)
18 VU2 Total Gain PRE ON ref
• Set the test equipment level to:
Level: +60
dB
μ
†
(–47 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound
after the adjustment is
completed.)
19 VU2 Total Gain PRE ON set
• Set the test equipment level to:
Level: OFF
Touch [SET].
(A beep sounds, and then
another beeps sound 10
seconds later.)
†
: The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.
Содержание IC-R8600
Страница 1: ...S 15404XZ C1 June 2017 SERVICE MANUAL COMMUNICATIONS RECEIVER iR8600...
Страница 9: ...3 2 FRONT UNIT DIM CTRL Q43 DIM CTRL Q41 TW CTRL IC52 D A CONVERTER IC102 BUFF IC103 FRONT CPU IC101...
Страница 84: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan S 15404XZ C1 2017 Icom Inc...