5-6
ADJUSTMENT
ADJUSTMENT ITEM DISPLAY
CONDITION
OPERATION
VU2 S-METER
20 VU2 S0 LEVEL
• Set the test equipment to:
Frequency: 625.0215
MHz
Modulation: None
Level: 0
dB
μ
†
(–107 dBm)
Touch [SET].
(A beep sounds, and then
another beeps sound 1
seconds later.)
21 VU2 S9 LEVEL
• Set the test equipment level to:
Level: +34
dB
μ
†
(–73 dBm)
22 VU2 S9+60 LEVEL
• Set the test equipment level to:
Level: +94
dB
μ
†
(–13 dBm)
23 VU2 dBu –10dB
• Set the test equipment level to:
Level: –10
dB
μ
†
(–117 dBm)
24 VU2 dBu 0dB
• Set the test equipment level to:
Level: 0
dB
μ
†
(–107 dBm)
25 VU2 dBu 10dB
• Set the test equipment level to:
Level: 10
dB
μ
†
(–97 dBm)
26 VU2 dBu 20dB
• Set the test equipment level to:
Level: 20
dB
μ
†
(–87 dBm)
27 VU2 dBu 40dB
• Set the test equipment level to:
Level: 40
dB
μ
†
(–67 dBm)
28 VU2 dBu 60dB
• Set the test equipment level to:
Level: 60
dB
μ
†
(–47 dBm)
29 VU2 dBu 80dB
• Set the test equipment level to:
Level: 80
dB
μ
†
(–27 dBm)
VU12-flat
30 VU12 BPF1 flat ( M)
• Set the test equipment to:
Frequency: 40.0215
MHz
Modulation: None
Level: +40
dB
μ
†
(–67 dBm)
31 VU12 BPF1 flat (L)
• Set the test equipment to:
Frequency: 30.0215
MHz
32 VU12 BPF1 flat (H)
• Set the test equipment to:
Frequency: 49.9815
MHz
33 VU12 BPF2 flat ( M)
• Set the test equipment to:
Frequency: 65.0215
MHz
34 VU12 BPF2 flat (H)
• Set the test equipment to:
Frequency: 79.9815
MHz
35 VU12 BPF3 flat ( M)
• Set the test equipment to:
Frequency: 105.0215
MHz
36 VU12 BPF3 flat (L)
• Set the test equipment to:
Frequency: 80.0215
MHz
37 VU12 BPF3 flat (H)
• Set the test equipment to:
Frequency: 129.9815
MHz
38 VU12 BPF4 flat ( M)
• Set the test equipment to:
Frequency: 165.0215
MHz
39 VU12 BPF4 flat (L)
• Set the test equipment to:
Frequency: 130.0215
MHz
40 VU12 BPF4 flat (H)
• Set the test equipment to:
Frequency: 199.9815
MHz
41 VU12 BPF5 flat ( M)
• Set the test equipment to:
Frequency: 260.0215
MHz
42 VU12 BPF5 flat (L)
• Set the test equipment to:
Frequency: 200.0215
MHz
43 VU12 BPF5 flat (H)
• Set the test equipment to:
Frequency: 319.9815
MHz
44 VU12 BPF6 flat ( M)
• Set the test equipment to:
Frequency: 410.0215
MHz
45 VU12 BPF6 flat (L)
• Set the test equipment to:
Frequency: 320.0215
MHz
46 VU12 BPF6 flat (H)
• Set the test equipment to:
Frequency: 499.9815
MHz
47 VU12 BPF7 flat (L)
• Set the test equipment to:
Frequency: 500.0215
MHz
48 VU12 BPF7 flat (M1)
• Set the test equipment to:
Frequency: 580.0215
MHz
49 VU12 BPF7 flat (M2)
• Set the test equipment to:
Frequency: 670.0215
MHz
50 VU12 BPF7 flat (H)
• Set the test equipment to:
Frequency: 749.9815
MHz
5-4
VU RECEIVE ADJUSTMENT (CONTINUED)
†
: The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.