42
8
DSC OPERATION
New2001
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
■
DSC Settings
On the “DSC Settings” screen, you can make settings on
the DSC call related items.
Position Input
See “
Entering the position and time
” on page 21 for details.
Individual ID
See “
Entering an Individual ID
” on page 19 for details.
Group ID
See “
Entering a Group ID
” on page 20 for details.
Auto ACK
The Auto ACK function automatically sends an
Acknowledgement call when the following calls are received.
•
Individual call (Default: Differs depending on the version)
•
Position Request call (Default: Manual)
•
Test call (Default: Auto)
Manual
: Manually send an Acknowledgement call.
Auto
: Automatically send an Acknowledgement call.
CH Auto Switch
(Default: Accept)
Select whether or not to automatically switch to channel
16 or the specified channel, or select whether to switch or
ignore the call.
Accept
: After receiving a DSC call, the transceiver remains
on the operating channel for 10 seconds. After
that, the transceiver automatically switches to the
channel that is specified on the DSC call.
Ignore
: After receiving a DSC call, if you do not push the
software key below [ACPT] in 10 seconds, the
transceiver ignores the call, and then remains on
the current operating channel.
Manual
: After receiving a DSC call, you can select whether
or not to accept the received DSC call.
DSC Switch
(Default: On)
Select whether or not to receive and send DSC calls.
L
You can send Distress calls despite of this setting.
On
:
Receives and sends DSC calls.
Off (TEMP)
: Does not receive or send DSC calls until you
turn OFF the transceiver.
Off
:
Does not receive or send DSC calls.
TIP:
When “Auto” is set to the Individual call, the
Acknowledgement “Unable to Comply” is automatically sent when
the call is received.