5
ELECTRICAL SHOCK HAZARD
– Turn off power at the main service panel by removing the fuse
or switching the appropriate circuit breaker to the Off position before removing the existing
thermostat.
IMPORTANT:
Thermostat installation must conform to local and national building and electrical codes and
ordinances.
IMPORTANT:
This thermostat is compatible with 100% lockout systems. To reset the system, turn thermostat
to Off position for at least 60 seconds.
Note:
Mount the thermostat about five feet above the floor. Do not mount the thermostat on an outside wall,
in direct sunlight, behind a door, or in an area affected by a vent or duct.
1. Turn off power to the heating and cooling system by removing the fuse or switching off the appropriate circuit
breaker.
2. Put
Mode
switch in
Off
position.
3. Put
Fan
switch in
Auto
position.
4. To remove cover, insert and twist a coin or screwdriver
in the slots on the sides of the thermostat.
5. Put thermostat base against the wall where you plan to mount it (Be sure wires will feed through the wire opening
in the base of the thermostat).
6. Mark the placement of the mounting holes.
7. Set thermostat base and cover away from working area.
8. Using a 3/16” drill bit, drill holes in the places you have marked for mounting.
9. Use a hammer to tap supplied anchors in mounting holes.
10. Align thermostat base with mounting holes and feed the control wires through wire opening.
11. Use supplied screws to mount thermostat base to wall.
Cool Off Heat Emer
Auto
On
Mode
Fan
To Install Thermostat
Содержание SC2201