background image

08162 / TH114-A-240D / TL7235

      69-2022-1                    2007-10-17                    1/2

Non-programmable Thermostat - Installation and User Guide

This thermostat can be connected to an electric heater to control the
room temperature.

*

The thermostat indicates how much heating is required to maintain the desired
temperature. For example, 

 is displayed when heating is at 40 percent.

The configuration switch is located at the back of the control module
(faceplate). The switch allows you to select between °C and °F

Turn off power to the heating system at the main electrical panel
to avoid electrical shock. The installation should be carried out
by an electrician.

 

High voltage thermostats must be installed onto an electrical
box. 

For a new installation, choose a location about 5 ft. above the
floor and on an inside wall.

The thermostat must be installed on an inside wall facing the
heating system.

Avoid locations where there are air drafts (top of staircase, air
outlet), dead air spots (behind a door), direct sunlight or con-
cealed chimneys or stove pipes.

n

Connect the power base wires to the power supply and load 
using solderless connectors for copper wires. 

o

Push the excess length of the high-voltage wires back into the 
electrical box.

p

Secure the power base to the electrical box using the provided 
screws. 

q

Install the control module onto the base.

r

Apply power to heating system.

NOTE: 

Always keep the thermostat's vents clean and unobstructed.

As soon as the thermostat is powered, it undergoes a
series of tests before displaying the actual temperature.

LO

: The measured temperature is below the display

range. Heating is activated.

HI

: The measured temperature is above the display

range.

n

Description

1.

Display

% of heating

1 to 24%

25 to 49% 50 to 74% 75 to 99%

100%

o

Configuration

2.

Backlight button

Temperature 
adjustment buttons

Set the switch to 
Off to cut power to 
the heater

Heating indicator *

Temperature 
display

Appears when 
the setpoint is 
displayed

p

Installation

3.

q

Power-up

4.

r

Error Messages

5.

Power

Load

08162

TH114-A-240D

TL7235

400-114-014-B_69-2022-1 (Cadet TL7235) ENG.fm  Page 1  Wednesday, October 17, 2007  8:58 AM