15
SimpleComfort
®
2201
W2
L
C
Y2
E
G
B
O
Y1
R
SimpleComfort
®
2201 Electronic Thermostat Conversion to:
Payne Reliant and Endura Model Heat Pump Systems
Payne Reliant and Endura Model
Low V
oltage T
erminal Board
R
Y
O
G
E
W2
L
C
W3
24 VAC, Return
Compressor Contactor
Reversing Valve (Cooling Mode)
Fan Contactor Circuit
Emergency Heating Circuit
2nd Stage Heating Circuit
System Monitor LED
24 VAC, Common
3rd Stage Heating Circuit
Note 1:
W3 terminal on Payne PCB capped at PCB.
(capped)
Содержание SC2201