6
12. Insert stripped, labeled wires in matching wire terminals. See Wiring Diagrams section of this manual (Pages 11-
24).
CAUTION!
:
Be sure exposed portion of wires does not touch other wires.
13. Tighten screws on terminal block. Gently tug wire to be sure of proper connection. Double check that each wire is
connected to the proper terminal.
14. Seal hole for wires with non-flammable putty or insulation.
15. Replace cover on thermostat by snapping it in place.
16. Turn on power to the system at the main service panel.
17. Test thermostat operation as described in the following section.
CAUTION!
:
Do not switch system to cool if the outdoor temperature is below 50°F (10°C). This can damage
the air conditioning system and may cause personal injury.
1. Put the
Mode
switch to
Cool
position.
2. Press the button until the temperature setting is at least 3 degrees below the room
temperature. The air conditioning system and fan should turn on within a few seconds.
3. Put the
Mode
switch in the
Off
position. The air conditioning system should turn off.
The fan may have a delay.
Note:
Pressing the
Reset
button will bypass the 5-minute anti-short cycle
compressor protection.
Cool Off Heat Emer
Cool Off Heat Emer
Mode
Mode
Testing the Thermostat
Содержание SC2201