18
5.6.3 DOOR
ADJUSTMENT
(OPENING ON THE RIGHT)
Vertical adjustment
1. With the door ajar, loosen the counter-nuts (5s) of the hinge units.
2. Act on the adjustment nuts (4s) to lift or lower the door by centring the gasket on the stop plate (see fig-
ure), then block the counter-nuts (5s).
3. Close the door and centre the tie-rod (1d) on the mechanical tube (9d), proceeding as in point 2.
Horizontal adjustment
Close the door using the lever and check that there is equal distance on both sides, between the stop plate
and the band.
Otherwise, proceed as follows:
1. With the door ajar, loosen the locking nuts (7s) of the hinge units.
2. Act on the ferrule (8s) to adjust the distance depth-wise.
3. Screw the nuts (7s) and block the conical washers on the mechanical tubes.
Check the proper adjustment in depth ensuring that the door, manually pushed up to the stop plate, naturally
returns remaining ajar. This is to ensure the hinge side fume seal.
For any problems related to the reversal and adjustment of the door, we recommend contacting our
local Authorised Technical Assistance Centre.
IMPORTANT:
Incorrect door adjustment with consequent damage to people and property
voids the warranty conditions.
OPENING UNIT
HINGE UNIT
KEY
1. Tie-rod
with
pin
2. Upper
bracket
3. Lower
bracket
4. Vertical adjustment nut
5. Locking counter nut
6. Vertical
tie-rod
plain
washer
7. Horizontal locking nut
8. Perforated ferrule for opening (s)
Wrench ferrule for hinge (d)
9. Door mechanical tube
10. Conical centring washer
11. Opening lever washer
12. Opening lever
Содержание GREENOx BT COND 180
Страница 31: ......