22
Detailed description of each mode
4-26: Specification of whether surrounding temperature
compensation will be used
This category is used to compensate for the surrounding
temperature (located at the suction side of the compressor)
1 : Temperature compensation value setting for 10℃ or lower
This sets the temperature compensation value of the ambient
temperature to the environmental temperature of 10℃ or lower.
2 : Temperature compensation value setting for 20℃ or lower
This sets the temperature compensation value of the ambient
temperature to the environmental temperature of 20℃ or lower.
3 : Temperature compensation value setting for 30℃ or lower
This sets the temperature compensation value of the ambient
temperature to the environmental temperature of 30℃ or lower.
4 : Temperature compensation value setting for 40℃ or lower
This sets the temperature compensation value of the ambient
temperature to the environmental temperature of 40℃ or lower.
5 : Temperature compensation value setting for 41℃ or higher
This sets the temperature compensation value of the ambient
temperature to the environmental temperature of 41℃ or higher.
4-27 : Sale lever no return judgment time setting
When the lever does not return to the original position after the
ejection of the soft freezer, an alarm is set off after the time
that was set for this category.
4-28 : Hopper temperature compensation function setting
The temperature sensor on the bottom of the hopper detects
the temperature of the raw material in the hopper.
Models with an impeller almost have the same temperature,
but a temperature difference can appear in the models
that don't have an impeller. Therefore, it is the category
to compensate this temperature difference.