Detailed description of each mode
4-11: Environmental temperature detect function setting
The function to detect the environmental temperature
can be turned ON/OFF. Environmental temperature is the
temperature of the air coming into the compressor.
Therefore, the temperature for this category can be high and
a warning message can be given if the place of installation
is small and has no ventilation.
Then the installation environment must be improved.
4-12 : No load detection function setting
The no load detection function can be turned ON/OFF.
"No load" means the raw material inside the cylinder exists
in a liquid condition. The motor current is then called
"no load current."
If this function is set to on, power is allowed to the product
and the no load current is remembered when the temperature
of the cylinder is higher than 5℃.
4-13 : Voltage standard value setting
Measure the voltage at the place of installation and
enter the standard value. This product guarantees ±10%
of the supply power. When it is outside of the range
a warning sound is given.
If used continually, the product can have problems.
4-14 : Button sensitivity setting
This sets button sensitivity.
Asmaller number means more sensitivity and a larger
number means less sensitivity.
4-15 : Voice language selection
The language set in this category gives voice guidance,
and a total 2 languages are embedded.
: Korean, : English
4-16 : Set motor current value correction
This is the function for performing overall compensation
when the measured motor current is different
from the actual measurement value.
4-17 : Air pump selection
If the model has an air pump, this category can be turned
on to control the operation of the air pump.
1: Operation time setting during the initial operation
Set the operation time of the air pump when beginning
initial operation.