WASH CYCLE FOR ALL IM-SERIES MACHINES
1.
With the power switch in the ‘OFF’ position, add the
appropriate amount of ice machine cleaner or sanitizer to the water trough.
NOTE: If the machine is in the ‘ICE’ mode, first place the
power switch in the ‘OFF’ position and wait for the
machine to finish its current cycle and stop.
2.
Place the power switch on the front panel to the ‘WASH’ position to run the wash cycle.
3.
Water inlet solenoid valve opens for a 30 seconds to fill.
4.
Water pump then runs for 10 minutes, circulating the mix through the water trough, pump,
connecting hose, water distributor, and evaporator.
5.
Dump valve solenoid opens for a 40 second flush.
6.
Water inlet solenoid valve opens for a 30 second fill.
7.
Water pump then runs for 1.5 minutes to circulate fresh water.
8.
Dump valve solenoid opens for a 40 second flush.
9.
Steps 5-7 repeats five times.
WARNING! Do NOT mix ice machine cleaner and sanitizer together. Use one or the other separately.
Mixing cleaner & sanitizer together can cause severe bodily injury.
WARNING! Use ONLY nickel safe ice machine cleaner.