Check the ice thickness sensor.
The ice thickness sensor should NOT be touching the evaporator plate. There should be approximately
¼”
-
⅜” of space between the sensor and the evaporator. Turn the adjustment screw on the sensor
clockwise to put more space between the sensor and the evaporator. Turn the adjustment screw
counter-clockwise to put less space between the sensor and evaporator.
Part of the installation process is to check that the ice thickness sensor is properly
adjusted. Too close to the evaporator and the customer will have hollow cubes (or
worse) the machine won’t make ice at all. Too far from the evaporator and you’re
freeze time will be too long and the customer will complain of “thick” or “chunky” ice.
Lift the water curtain up and out of the curtain hangers to expose the ice thickness
sensor. No need to bend the curtain to remove it.
Pre-Start Up Tips
19
¼”
-
⅜”
Содержание IM-1100
Страница 1: ...IM 1100 Remote Installation Service Manual ...
Страница 2: ...2 IM 1100 Remote Specifications ...
Страница 3: ...3 IM 1100 Remote Specifications ...
Страница 31: ...31 IM 1100 Remote Wiring Diagram ...
Страница 37: ...37 IM Series Service Tips Pinching Tubing Re rounding Tubing ...
Страница 48: ...Pressures Cycle Times IM 1100 RC RH Pressures Cycle Times 48 ...
Страница 49: ...Tubing Schematic IM 1100 RC RH Tubing Schematic 49 ...
Страница 55: ...THANK YOU 1 15 2022 ...