![ICETEAM 1927 SL193-011342 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/iceteam-1927/sl193-011342/sl193-011342_electronic-manual_3397416044.webp)
SL193-011342 ED00 10-2018
41
Step
Contents
T75
Alarm PR1
Number of interventions of the pressure gauge to view the high-pressure
switch alarm: "
Pressure switch
".
Setting this value to 000, the control is deactivated (does not display the
alarm).
Note
: In each change of function, the count of interventions of the
pressure switch is RESET.
T77
Al. TimeoutPrd
Activates (Yes) or deactivates (No) the alarm "
Timeout Prd
”.
T81
Dif. Set PP
Value of the increase applied on the reading of the absorption of the
pump in the pump tube calibration process (see Calibration Pump Tube).
T82
Time Cab. x Defrost
The cabinet has a timer cycle linked to a cooling process. When the time
programmed is reached in step Time Cab. x Defrost (T82), an automatic
defrost activates for 140
’’
and this timer goes back to zero.
T84
Minutes Test Tube
Time of the pump tubes calibration (see Calibration Pump Tubes).
T85
Set TEC Cleaning
When the Hot Cleaning function is selected, the EVRC is activated with MA
and MC until reaching the value set in this step.
If the temperature has already been reached when selecting the function,
the machine stops.
T86
Reset Hours counter
1 = reduction to zero hours MA, MP, cones and events
2 = reduction to zero cones
3 = reduction to zero events
4= reduction to zero hours MA
5= reduction to zero hours MP
Once set, activates the reduction to zero at the exit of the programming
and places on 000 again (no reduction to zero) automatically.
T87
Ohm Level On
Step for the level sensor calibration.
Содержание SL193-011342
Страница 1: ...Electronic Manual English Version Ed00 10 2018 SL193 011342 P1...
Страница 2: ......
Страница 4: ...File name SW version Date Changes to previous version P1 1_00 mot 1_00 22 10 2018 First version...
Страница 6: ...XIX C Ohm table 48 XX Sensor calibration after electronic board replacement 50...
Страница 12: ...SL193 011342 ED00 10 2018 9 Figure 3 PR Left Side PR EVRC TEC EVRC TEV EVRC Figure 4 5 TEC TEV...
Страница 38: ...SL193 011342 ED00 10 2018 35 Step Contents U14 Wash hour Setting of display hour of the Wash today alarm...
Страница 52: ...SL193 011342 ED00 10 2018 49 85 1508 90 1557 9 95 1608 7 100 1660 4 105 1713 110 1766 5 115 1820 9...
Страница 57: ...REALIZED by VERIFIED by APPROVED by Francesco Curatolo Francesco Curatolo Salvador Carbonell Salvador Carbonell...