ICETEAM 1927 SL193-011342 Скачать руководство пользователя страница 23

SL193-011342   ED00 10-2018  

20 

 

 

MIX OUT

 

If the minimum level of the tank is uncovered, the first line of the display shows in fixed mode 

Mix Out.  

In this case, the low level led light of the tank, on the keyboard turns on MIX and the alarm 

rings continuously. 

The second display line shows the cones that can still be removed (Last Cones) before the 

machine goes on automatically onto STORAGE.  

The number of cones that can still be removed is indicated on step Last cones (T17) of the 

machine programming.  

 

 

 

 

NOTE: With the message Mix Out! the following PRODUCTION screens can not be accessed.

 

 

If the tank level is covered before the cones finish, the alarm will disappear.  

 

 

 

 

 

 

 

 

MIX OUT!               

Cones 5 

Содержание SL193-011342

Страница 1: ...Electronic Manual English Version Ed00 10 2018 SL193 011342 P1...

Страница 2: ......

Страница 3: ...k is reserved exclusively for QUALIFIED TECHNICIANS Attached are electrical scheme and programming table When turned on the machine carries out a functional test of the display and all LEDs light up T...

Страница 4: ...File name SW version Date Changes to previous version P1 1_00 mot 1_00 22 10 2018 First version...

Страница 5: ...ST 19 Automatic Defrost 19 Safety Defrost 19 VI Cleaning Load Calibration pump tubes 21 Calibration of the pump tubes 21 Hour counter MA and MP 24 VII Wash Days 25 VIII Keypad Locked 26 IX Alarms 27 P...

Страница 6: ...XIX C Ohm table 48 XX Sensor calibration after electronic board replacement 50...

Страница 7: ...t EVRC Electrovalve Heat Cylinder EVRV Cab Electrovalve Heat Cabinet EVAria Electrovalve Air Cylinder MA Beater Motor MC Compressor Motor MIR Spigot micro switch MP Pump Motor MV Fan motor MVCab Cabin...

Страница 8: ...00 10 2018 5 Control panel When a key is accepted the keypad emits an acoustic sound Key Operation STOP EXIT CLEANING TOUCHPAD BLOCKED SAVE PRODUCTION SAVE PUMP INCREASE STORAGE DECREASE RESET ICE CRE...

Страница 9: ...version For example It means software version is 1 00 In case of you request assistance get the best possible support from IceTeam1927 the technician will always need to specify software version numb...

Страница 10: ...SL193 011342 ED00 10 2018 7 Thermostats Probes Solenoids and Pressure Switches positions T RC EVRC IMS EVRC MIR EVRC...

Страница 11: ...SL193 011342 ED00 10 2018 8 Figure 1 EVAria TEV Cab front side Figure 2 TRC back side TEV Cab EVRC EVAria EVRC T RC EVRC...

Страница 12: ...SL193 011342 ED00 10 2018 9 Figure 3 PR Left Side PR EVRC TEC EVRC TEV EVRC Figure 4 5 TEC TEV...

Страница 13: ...SL193 011342 ED00 10 2018 10 Figure 4 EVRV EVRC EVFC EVFV T CN back side EVRV EVRC EVRC EVRC EVFC EVRC EVFV EVRC T CN EVRC...

Страница 14: ...ting to zero the hour counter MA MP To reset the MP hours counter to zero The MP counter resets to zero automatically after having performed a calibration of the pump pipe see CLEANING LOAD CALIBRATIO...

Страница 15: ...e machine must be stopped Press and hold STOP for 3 The display will show the following sequence The last screen corresponds to the last stored event To scroll the events press the INCREASE button nex...

Страница 16: ...eeps ON for a time programmed Delay beater T07 In this moment the cabinet will be cooled if necessary TEV Storage Temp T23 MC and MV keep ON and MVcab and EVFV will switch ON Once the HOT is reached i...

Страница 17: ...U18 or T41 Time ON s air time OFF s liquid T20 T21 1 0 2 0 56 19 14 2 0 2 0 48 17 12 3 0 2 0 40 15 10 4 0 2 0 32 13 8 5 0 2 0 24 11 6 6 0 2 0 16 9 4 It also has value 7 free and adjustable in the Prog...

Страница 18: ...ording to that established in the step Timeout Prd it is necessary to force the end of cycle as if the HOT had been reached and the events alarm memorized with Timeout Prd Alarm in the display If the...

Страница 19: ...cond the remaining 75 tenths of second EVFCab ON If TGC 8 EVFCab OFF during 110 75 tenths of second the remaining 75 tenths of second EVFCab ON If TGC 5 EVFCab OFF during 100 75 tenths of second the r...

Страница 20: ...that the cylinder is getting colder By pressing PRODUCTION again you can see the temperatura of the refrigerant at the entrance to the compressor TGC and in the condenser TCN and the fan speed By pres...

Страница 21: ...the cylinder are controlled When TEC becomes higher than the set storage temperature hysteresis 2 C the cylinder is cooled Between the interval of one and the other cylinder temperature control the c...

Страница 22: ...lower tray The active outputs during the process are MC and EVRV There are two types of Defrost Automatic Defrost The cabinet has a timer cycle linked to a cooling process When the time programmed is...

Страница 23: ...ings continuously The second display line shows the cones that can still be removed Last Cones before the machine goes on automatically onto STORAGE The number of cones that can still be removed is in...

Страница 24: ...alibration pump tubes function is accessed This process must be performed whenever the pump tube is replaced the pump a pump motor or an electronic control unit Pressing the key PUMP it is requested t...

Страница 25: ...en MP continues to work until reaching it Set Absor PP T29 Cleaning Hot Cleaning By pressing the key STORAGE twice the cleaning function is accessed This function activates MA with MP for 30 Then the...

Страница 26: ...ctive and EVRC MC activate until the temperature of the cylinder reaches the value Set TEC Cleaning defined in step T85 on Programming Table In this window the display shows in the first line top TEC...

Страница 27: ...SL193 011342 ED00 10 2018 24 Hour counter MA and MP Pressing the key PRODUCTION from PRODUCTION function displays the MA and MP hours counter MP hours 00000 MA hours 00002...

Страница 28: ...therefore the MP MA and MC are activated until the product has the desired texture again The display will be The ice cream PRODUCTION function activates and the machine does not accept the function i...

Страница 29: ...from any function all the keys will be disabled and the CLEANING led light will flash This allows cleaning the keypad without causing accidental function changes The machine stays in the same functio...

Страница 30: ...higher than 126 for more than 4 sec the cylinder performs as if it has reached the set texture and the display shows the message Beater Blocked Check the connectors of the EVRC and EVRCab or and the s...

Страница 31: ...pears on STOP it is necessary to check replace the probe TEC because the full scale of the readable temperature of the central unit is read Low Amperage 0 This message is displayed in PRODUCTION when...

Страница 32: ...r than the value established in step Last cones is supplied in addition to viewing the message Mix Out the machine will go on to the status of Hot reached deactivating all the exits in the side in whi...

Страница 33: ...rs at the end of the second consecutive safety Defrost without having reached the set temperature in the Cabinet see Defrost The machine has to be placed on STOP and the evaporator must be cleaned man...

Страница 34: ...In the case of no power is the machine was CLEANING when the power comes back it will go to STOP If the machine was in PRODUCTION or STORAGE when the power comes back the machine returns to the same f...

Страница 35: ...lues through the procedure indicated in paragraph CALIBRATION OF PROBES IN THE CASE OF CHANGE OF CENTRAL UNIT The autosetup procedure adjust all the programmable values according to that indicated in...

Страница 36: ...ious event If no key is pressed for 30 or if STOP is pressed the machine will go on STOP The list of events will help us understand when and how many times an alarm has taken place N B The maximum num...

Страница 37: ...ION or CLEANING At this point the machine returns to STOP Step Contents U01 Hours Hours setting U02 Minutes Minutes U03 Day of the week Day of the week setting U04 Day of the month Day of the month se...

Страница 38: ...SL193 011342 ED00 10 2018 35 Step Contents U14 Wash hour Setting of display hour of the Wash today alarm...

Страница 39: ...HOT more sensitive during the extraction When the machine is in PRODUCTION and MIR excited after a decoupling of the compressor by HOT the compressor reactivates when the consistency indication appea...

Страница 40: ...el in the electrical box T11 Cyclic Timer PRODUCTION cycle timer Every 10 programmed in this step the beater will turn to test ice cream consistency T12 Trimmer HOT This value is automatically calibra...

Страница 41: ...level led has turned on Then the machine will go automatically onto STORAGE T20 T Air Period Value linked to the complete ON OFF cycle of the EVAria when the Overrun selected is 7 the higher the value...

Страница 42: ...tronic central unit the machine should not be taken to room temperature to calibrate the probes Check the temperature of the cabinet with a precision thermometer if the value detected is not 4 C shown...

Страница 43: ...New Lock Mode This is the keypad block mode If the value of step T50 is No the management of the blocked keypad is the previous that is flashing led light If the value is Yes with the value blocked t...

Страница 44: ...cess When the time programmed is reached in step Time Cab x Defrost T82 an automatic defrost activates for 140 and this timer goes back to zero T84 Minutes Test Tube Time of the pump tubes calibration...

Страница 45: ...9 Gain TEV Not used T90 Gain TEC Not used T91 Gain TCN To calibrate with water between 35 and 40 C T93 Gain 5 To calibrate when the hot cleaning has been performed with a precision thermometer on the...

Страница 46: ...ge regarding the HOT display a number will be shown that will be increasing When the cylinder reaches the texture HOT 120 the current read by the probe must be equal to the value of the beater motor I...

Страница 47: ...SL193 011342 ED00 10 2018 44 View of electronic boards The machine s electronics consists of a IC573700148 control unit...

Страница 48: ...J8 European amp scale both jumpers are positioned towards the inside part of the board J9 J7 USA amp scale both jumpers are positioned on the outside part of the board NOTE This machine uses a black...

Страница 49: ...es of the programming table previously copied from the old board and the calibration values of probes see chap Probe calibration in the event of control unit replacement to the new control unit and ch...

Страница 50: ...the new software from the computer to the CPU using M16C Flasher Once you have connected your PC RS232 or USB to the CPU serial switch on the machine Once M16C Flasher has been installed Start the pro...

Страница 51: ...ance read by a tester It is useful for verifying that sensors are functioning correctly TEMPERATURE C OHM 50 503 5 45 528 9 40 555 2 35 582 5 30 610 6 25 639 6 20 669 6 15 700 5 10 732 2 5 764 9 0 798...

Страница 52: ...SL193 011342 ED00 10 2018 49 85 1508 90 1557 9 95 1608 7 100 1660 4 105 1713 110 1766 5 115 1820 9...

Страница 53: ...tion procedure Set the machine to STOP mode and 1 Press PRODUCTION and RESET at the same time and keep them pressed for 10 2 Release buttons as soon as display shows Probe Setup 3 Now the display show...

Страница 54: ...30 For ex NOTE The first 3 values TCQ TMG PZG to program them in the new board Each value flashes for 10 then set probe TGC 7 The display shows TCN probe numerical values for 15 For ex NOTE The first...

Страница 55: ...s display shows Probe Setup 11 Now the display shows TEV probe numerical values for 30 For ex Set the previously noted values by editing the relevant flashing value using the INCREASE DECREASE buttons...

Страница 56: ...ocedure for the TGC probe 15 Press PRODUCTION when the display shows Probe Setup is displayed and then the following message will appear The procedure is complete TGQ TMG PZG TGC 550 358 05 001 Save S...

Страница 57: ...REALIZED by VERIFIED by APPROVED by Francesco Curatolo Francesco Curatolo Salvador Carbonell Salvador Carbonell...

Страница 58: ......

Отзывы: