SL193-011342 ED00 10-2018
15
NOTE:
If the consistency is below the value programmed in the step Set Hot (U16 user)
–
Hysteresis Hot - HOB
Hot Block (T49) - Wait! is shown on the display. This means the ice-cream is not ready to be removed.
To deactivate the message, adjust to zero the parameter HOB Hot Block (T49).
Ice in the cylinder
In PRODUCTION, if the TEC temperature reaches a value lower or the same as the step Ice
Cylinder, the Ice Cylinder alarm, which is memorized ONLY in the event, is generated.
The display does not view this alarm.
In this condition, all the outputs related to the cylinder are deactivated and the machine
then cools the cabinet, if necessary. When the PRODUCTION timeout finishes, the texture is
examined again if the TEC of the cylinders is greater than Ice Cylinder.
Timeout Prd
In PRODUCTION, if the texture does not reach the set in the time expected according to that
established in the step Timeout Prd., it is necessary to force the end of cycle, as if the HOT had
been reached and the events alarm memorized (with Timeout Prd. Alarm in the display).
If the Hot Block (T09) is not reached then the machine passes in STOP with Timeout Prd. alarm
on the display.
Blocked Beater
In PRODUCTION, if the texture reaches a value greater than 126 in 5
’’
., all the cylinder outputs
are deactivated and the machine cools the cabinet if necessary, with the alarm Blocked
Beater. This control is necessary to preserve the belt.
Cabinet
The cabinet is kept through the TEV probe. It cools when TEV
Storage Temp. (T23). In this
condition, the MC, MV, MVcab and EVFV activate, until reaching the set Temperature.
The cabinet and the cylinder never activate at the same time.
The cylinder has priority: Firstly, the cylinder is taken to texture and then the cabinet in
temperature. While the cabinet is in operation, if the cone is supplied, the cabinet stops and
the cold in the cylinder activates until the product has the texture again.
Sundae Ready!
TEV +4
°
C W- 14
Содержание SL193-011342
Страница 1: ...Electronic Manual English Version Ed00 10 2018 SL193 011342 P1...
Страница 2: ......
Страница 4: ...File name SW version Date Changes to previous version P1 1_00 mot 1_00 22 10 2018 First version...
Страница 6: ...XIX C Ohm table 48 XX Sensor calibration after electronic board replacement 50...
Страница 12: ...SL193 011342 ED00 10 2018 9 Figure 3 PR Left Side PR EVRC TEC EVRC TEV EVRC Figure 4 5 TEC TEV...
Страница 38: ...SL193 011342 ED00 10 2018 35 Step Contents U14 Wash hour Setting of display hour of the Wash today alarm...
Страница 52: ...SL193 011342 ED00 10 2018 49 85 1508 90 1557 9 95 1608 7 100 1660 4 105 1713 110 1766 5 115 1820 9...
Страница 57: ...REALIZED by VERIFIED by APPROVED by Francesco Curatolo Francesco Curatolo Salvador Carbonell Salvador Carbonell...
Страница 58: ......