SL193-011342 ED00 10-2018
32
Autosetup
If necessary, the autosetup must only be performed after the authorization by the staff of
IceTeam1927 staff.
ATTENTION: In an autosetup, the offset of the probes is reduced to zero. It is advised to put away the
Programming table before performing an autosetup. Specify the probe values through the procedure
indicated in paragraph: CALIBRATION OF PROBES IN THE CASE OF CHANGE OF CENTRAL UNIT.
The autosetup procedure adjust all the programmable values according to that indicated in
the column of each model in the programming table. To do this, turn the machine off and
turn it on again with the RESET button pressed. Keep pressed for
5’’
without pressing any key.
The display shows in sequence:
followed by an acoustic warning.
In this way, the machine is programmed with the default values.
Autosetup Done