7-4
Rev AA
Motor Volts Error
Power supply voltage
varies too much
Check the power supply
output
Faulty printer PCB
Replace the main printer
PCB
Faulty Motor
Check the motor and replace
if necessary
Printhead Volts
Error
Power supply voltage
varies too much
Check the power supply
output
Faulty printer PCB
Replace the main printer
PCB
Printer Hand Not
Set
Flash memory is lost
Use the CLARiTY
configuration CD
Motor Calibration
Required
Flash memory is lost
Use the CLARiTY
configuration CD
Printhead
Resistance Not
Set
Flash memory is lost
Set the resistance value from
the user interface
Webbing Error
Supply ribbon reel
eccentric (+1mm)
Replace the reel
End of Reel
Less than 20 meters of
ribbon remaining on reel
Replace the reel
Incorrect Reel
Size
Ribbon cores not fitted
Try using a different reel
Incorrect roll width fitted
Make sure that the software
reel width setting matches
the width of the reel that you
are using
Error
Message
Possible Causes
Remedies