4.
If
you
are
replacing
a
failed
power
supply,
remove
the
failed
power
supply
from
the
bay.
a.
Disconnect
the
power
cord
from
the
connector
on
the
back
of
the
failed
power
supply.
b.
Press
the
locking
latch
on
the
power
supply
handle
and
raise
the
power
supply
handle
to
the
open
position.
c.
Lift
the
failed
power
supply
out
of
the
bay.
5.
Raise
the
handle
on
the
new
power
supply
to
the
open
position.
6.
Place
the
new
power
supply
into
the
power
bay
in
the
chassis
and
fully
close
the
locking
handle.
7.
Connect
one
end
of
the
power
cord
for
the
new
power
supply
into
the
connector
on
the
back
of
the
power
supply;
route
the
power
cord
through
the
cable-management
arm
and
connect
the
other
end
of
the
power
cord
into
a
properly
grounded
electrical
outlet.
8.
Make
sure
that
the
ac
power
LED
on
the
rear
of
the
power
supply
and
the
ac
power
LED
on
the
top
of
the
power
supply
are
lit,
indicating
that
the
power
supply
is
operating
correctly.
If
the
server
is
turned
on,
make
sure
that
the
dc
power
LED
on
the
top
of
the
power
supply
is
lit
also.
9.
Continue
with
“Completing
the
installation”
on
page
35.
Replacing
the
battery
The
following
notes
describe
information
that
you
must
consider
when
replacing
the
battery
in
the
server.
v
When
replacing
the
battery,
you
must
replace
it
with
a
lithium
battery
of
the
same
type
from
the
same
manufacturer.
v
To
order
replacement
batteries,
call
1-800-772-2227
within
the
United
States,
and
1-800-465-7999
or
1-800-465-6666
within
Canada.
Outside
the
U.S.
and
Canada,
call
your
IBM
reseller
or
IBM
marketing
representative.
v
After
you
replace
the
battery,
you
must
reconfigure
the
system
and
reset
the
system
date
and
time.
v
To
avoid
possible
danger,
read
and
follow
the
following
safety
statement.
Statement
2:
CAUTION:
When
replacing
the
lithium
battery,
use
only
IBM
Part
Number
33F8354
or
an
equivalent
type
battery
recommended
by
the
manufacturer.
If
your
system
has
a
module
containing
a
lithium
battery,
replace
it
only
with
the
same
module
type
made
by
the
same
manufacturer.
The
battery
contains
lithium
and
can
explode
if
not
properly
used,
handled,
or
disposed
of.
Do
not:
v
Throw
or
immerse
into
water
v
Heat
to
more
than
100°C
(212°F)
v
Repair
or
disassemble
Dispose
of
the
battery
as
required
by
local
ordinances
or
regulations.
Chapter
2.
Installing
options
31
Содержание xSeries 365
Страница 1: ...IBM xSeries 365 Type 8861 and 8862 Option Installation Guide ERserver...
Страница 2: ......
Страница 3: ...IBM xSeries 365 Type 8861 and 8862 Option Installation Guide ERserver...
Страница 37: ...b Remove all fans See Replacing a hot swap fan on page 33 for instructions Chapter 2 Installing options 25...
Страница 52: ...40 IBM xSeries 365 Type 8861 and 8862 Option Installation Guide...
Страница 64: ...52 IBM xSeries 365 Type 8861 and 8862 Option Installation Guide...
Страница 67: ......
Страница 68: ...Part Number 13N0344 Printed in USA 1P P N 13N0344...