lit
continuously,
that
drive
is
faulty
and
needs
to
be
replaced.
If
the
green
hard
disk
drive
activity
LED
is
flashing,
the
drive
is
being
accessed.
4.
If
you
have
other
options
to
install
or
remove,
do
so
now;
otherwise,
go
to
“Completing
the
installation”
on
page
35.
Note:
If
the
server
has
a
RAID
controller
or
adapter
installed,
you
might
need
to
reconfigure
the
disk
arrays
after
installing
hard
disk
drives.
See
the
documentation
that
comes
with
the
adapter
for
more
information.
Replacing
the
CD-ROM
drive
Complete
the
following
steps
to
replace
the
CD-ROM
drive:
1.
Review
the
safety
information
beginning
on
page
v,
and
“Installation
guidelines”
on
page
11.
2.
Turn
off
the
server,
disconnect
all
power
cords
and
external
cables,
and
remove
the
top
cover
(see
“Removing
the
cover
and
bezel”
on
page
13).
Drive guide
Drive guide
Flex cable
Wire spring
Wire spring
Retention hook
Retention hook
Diskette drive
CD-ROM drive
3.
Slip
the
wire
spring
from
under
the
retention
hook
and
pull
it
away
from
the
drive.
Set
the
wire
spring
aside.
4.
Slide
the
drive
out
the
front
of
the
server.
5.
Slide
the
replacement
drive
into
the
bay.
6.
Align
the
holes
in
the
side
of
the
drive
with
the
hole
in
each
drive
guide.
7.
Push
each
end
of
the
wire
spring
through
the
hole
in
the
drive
guide
and
into
the
hole
in
the
drive,
beginning
with
the
front
hole;
then,
push
the
middle
of
the
wire
spring
under
the
retention
hook.
8.
If
you
have
other
options
to
install
or
remove,
do
so
now;
otherwise,
go
to
“Completing
the
installation”
on
page
35.
Installing
memory
modules
The
following
notes
describe
the
types
of
dual
inline
memory
modules
(DIMMs)
that
your
server
supports
and
other
information
that
you
must
consider
when
installing
DIMMs:
v
Your
server
supports
2.5
V,
184-pin,
error
correcting
code
(ECC),
double-data
rate
(DDR)
SDRAM,
PC2100
registered
DIMMs
with
Chipkill
memory
protection
™
.
v
DIMMs
can
be
removed
and
replaced
through
the
access
doors
on
the
top
of
the
memory
cassette.
v
You
can
increase
the
amount
of
memory
in
the
server
by
replacing
the
DIMMs
with
higher-capacity
DIMMs
or
installing
additional
pairs
of
DIMMs
in
open
sockets.
The
server
supports
512
MB,
1
GB,
and
2
GB
DIMMs.
See
the
18
IBM
xSeries
365
Type
8861
and
8862:
Option
Installation
Guide
Содержание xSeries 365
Страница 1: ...IBM xSeries 365 Type 8861 and 8862 Option Installation Guide ERserver...
Страница 2: ......
Страница 3: ...IBM xSeries 365 Type 8861 and 8862 Option Installation Guide ERserver...
Страница 37: ...b Remove all fans See Replacing a hot swap fan on page 33 for instructions Chapter 2 Installing options 25...
Страница 52: ...40 IBM xSeries 365 Type 8861 and 8862 Option Installation Guide...
Страница 64: ...52 IBM xSeries 365 Type 8861 and 8862 Option Installation Guide...
Страница 67: ......