Table 11. RAID controller LEDs
Icon
LED
Color
Operating states
1
Fault
Amber
v
Off
- Normal operation.
v
On
- One of the following situations has
occurred:
– The RAID controller has failed.
– The RAID controller was placed offline.
Host loop
Green
v
On
- Normal operation.
v
Off
- One of the following situations has
occurred:
– The host loop is down, not turned on,
or not connected.
– A SFP has failed, or the host port is not
occupied.
– The RAID controller circuitry has failed,
or the RAID controller has no power.
Cache active
Green
v
On
- There is data in the RAID controller
cache.
v
Off
- One of the following situations has
occurred:
– There is no data in cache.
– There are no cache options selected for
this array.
– The cache memory has failed, or the
battery has failed.
+
Battery
Green
v
On
- Normal operation.
v
Flashing
- The battery is recharging or
performing a self-test.
v
Off
- The battery or battery charger has
failed.
Controller
fault
Expansion
by-pass
Expansion
10BT
2Gb/s
2Gb/s
10101
100BT
Battery
charging
Expansion link indicator
Cache
active
10BT
100BT
Host 1
Host 1
indicator
Host 2
indicator
Host 2
+
2Gbps
Figure 36. RAID controller LEDs
44
IBM TotalStorage FAStT600 Fibre Channel Storage Server: Installation and User’s Guide
Содержание TotalStorage FAStT600
Страница 1: ...IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide GC26 7531 01...
Страница 2: ......
Страница 3: ...IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide GC26 7531 01...
Страница 8: ...vi IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 12: ...x IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 16: ...xiv IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 30: ...xxviii IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 40: ...10 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 78: ...48 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 102: ...72 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 108: ...78 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 114: ...84 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 122: ...92 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 128: ...98 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 133: ......
Страница 134: ...Part Number 24P8202 Printed in U S A GC26 7531 01 1P P N 24P8202...