Table 14. Storage server troubleshooting (continued)
Problem
indicator
Component
Possible cause
Possible solutions
All green LEDs off All CRUs
Subsystem
power is off
Check that all storage-server
power cords are plugged in and
the power switches are on. If
applicable, check that the main
circuit breakers for the rack are
turned on.
AC power failure
Check the main circuit breaker
and ac outlet.
Power supply
failure
Replace the power supply.
Midplane failure
Have the midplane replaced
(service technician only).
Amber LED
flashing
Drive CRUs
Drive identify is in
process
No corrective action is needed.
One or more
green LEDs off
Power supply
CRUs
Power cord
unplugged or
switches turned
off
Make sure that the power cord is
plugged in and the power-supply
switches are turned on.
All drive CRUs
Midplane failure
Have the midplane replaced
(service technician only).
Front panel
Power supply
problem
Make sure that the cords are
plugged in and power supplies
are turned on.
Hardware failure
If any other LEDs are on, replace
the midplane (service technician
only).
Battery
Battery failure
Replace the battery.
Cache active
The cache is
disabled
Use the storage-management
software to enable the logical
drive read and write cache
settings.
The cache
memory has
failed
Replace the RAID controller.
The cache
battery has failed
Use the storage-management
software to check and replace
the battery.
Host loop
Host or switch is
off or has failed
Check if host or switch is on.
Replace attached devices that
have failed.
Fibre-channel
cable has failed
Ensure that the fibre-channel
cables are undamaged and
properly connected.
SFP has failed
Ensure SFP is seated properly;
replace SFP.
RAID controller
has no power or
has failed
Ensure that the unit is powered
on. Replace RAID controller.
Chapter 6. Solving problems
75
Содержание TotalStorage FAStT600
Страница 1: ...IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide GC26 7531 01...
Страница 2: ......
Страница 3: ...IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide GC26 7531 01...
Страница 8: ...vi IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 12: ...x IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 16: ...xiv IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 30: ...xxviii IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 40: ...10 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 78: ...48 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 102: ...72 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 108: ...78 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 114: ...84 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 122: ...92 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 128: ...98 IBM TotalStorage FAStT600 Fibre Channel Storage Server Installation and User s Guide...
Страница 133: ......
Страница 134: ...Part Number 24P8202 Printed in U S A GC26 7531 01 1P P N 24P8202...