Table for Intervention Conditions of External Cartridge Labels
Table 19. Intervention Required Conditions relating to external cartridge labels
Intervention Required Condition
Resolution Actions
Message
A duplicate volser (xxxxxx) was ejected to the
convenience I/O station.
Probable Cause
During an inventory or inventory update operation, a
cartridge was found whose external volume serial
number, xxxxxx, is the same as that of another cartridge
in the library. The volume was placed in the convenience
I/O station. The library does not support more than one
cartridge with the same volume serial number.
1. Remove the cartridge from the convenience I/O
station.
2. Determine why the cartridge is a duplicate and take
corrective action.
Message
A duplicate volser (xxxxxx) was ejected to
high-capacity facility cell: yyyy.
Probable Cause
During an inventory or inventory update operation, a
cartridge was found whose external volume serial
number, xxxxxx, is the same as that of another cartridge
in the library. The convenience I/O station is either not
installed, is full or is unavailable. The volume was placed
in high-capacity facility cell, yyyy. The library does not
support more than one cartridge with the same volume
serial number.
1. Place the library system in pause mode.
2. Open the appropriate enclosure door.
3. Remove the cartridge from the high-capacity facility.
4. Determine why the cartridge is a duplicate and take
corrective action.
5. Close the enclosure door.
6. Place the library system in auto mode.
Message
A duplicate volser (xxxxxx) was left in the
convenience I/O station.
Probable Cause
During an insert operation, a cartridge was found whose
external volume serial number, xxxxxx, is the same as
that of another cartridge in the library. The library does
not support more than one cartridge with the same
volume serial number.
1. Remove the cartridge from the convenience I/O
station.
2. Determine why the cartridge is a duplicate and take
corrective action.
Message
A duplicate volser (xxxxxx) was left in high-capacity
facility cell: yyyy.
Probable Cause
During an insert operation, a cartridge was found in
high-capacity facility cell, yyyy, whose external volume
serial number, xxxxxx, is the same as that of another
cartridge in the library. The library does not support more
than one cartridge with the same volume serial number.
1. Place the library system in pause mode.
2. Open the appropriate enclosure door.
3. Remove the cartridge from the high-capacity facility.
4. Determine why the cartridge is a duplicate and take
corrective action.
5. Close the enclosure door.
6. Place the library system in auto mode.
288
Magstar 3494 Tape Library Operator Guide
Содержание Tape Library Magstar 3494
Страница 1: ...Magstar 3494 Tape Library Operator Guide GA32 0280 09 IBM...
Страница 2: ......
Страница 3: ...Magstar 3494 Tape Library Operator Guide GA32 0280 09 IBM...
Страница 20: ...xviii Magstar 3494 Tape Library Operator Guide...
Страница 22: ...xx Magstar 3494 Tape Library Operator Guide...
Страница 27: ...A 0 6 C 0 0 4 1 Figure 2 Control Unit Frame Functional Components 3490E Front View Chapter 1 Introduction 5...
Страница 52: ...30 Magstar 3494 Tape Library Operator Guide...
Страница 62: ...40 Magstar 3494 Tape Library Operator Guide...
Страница 84: ...62 Magstar 3494 Tape Library Operator Guide...
Страница 106: ...84 Magstar 3494 Tape Library Operator Guide...
Страница 280: ...258 Magstar 3494 Tape Library Operator Guide...
Страница 326: ...304 Magstar 3494 Tape Library Operator Guide...
Страница 358: ...336 Magstar 3494 Tape Library Operator Guide...
Страница 374: ...352 Magstar 3494 Tape Library Operator Guide...
Страница 377: ......
Страница 378: ...IBMR Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber GA32 0280 09...