5. Press the Auto mode button on the operator panel.
6. Observe the Auto mode LED on the operator panel. The LED flashes until the
library is in Auto mode and then stays lit.
Note: If the high availability model is installed, the output facility still uses cells in
the control unit. The cells in the service bays are not available to the library.
Removing Ejected Cartridges from the High-Capacity Output Facility
1. Press the Pause button on the operator panel.
2. Observe the Pause mode LED on the operator panel. The LED flashes until the
library is in Pause mode and then stays lit.
3. Unlock and open the control unit frame front door and retrieve the ejected
cartridges from the area defined as the high-capacity facility output area.
4. Shut and lock the control unit frame door.
5. Press the Auto mode button on the operator panel.
6. Observe the Auto mode LED on the operator panel. The LED flashes until the
library is in Auto mode and then stays lit.
Note: If the high availability model is installed, the output facility still uses cells in
the control unit. The cells in the service bays are not available to the library.
Removing Ejected Cartridges from the High-Capacity Input/Output
Facility
1. Press the Pause button on the operator panel.
2. Observe the Pause mode LED on the operator panel. The LED flashes until the
library is in Pause mode and then stays lit.
3. Unlock and open the frame door that contains the High-Capacity Input/Output
facility and retrieve the ejected cartridges from the area defined as the
High-Capacity Input/Output facility.
4. Shut and lock the frame door.
5. Press the Auto mode button on the operator panel.
6. Observe the Auto mode LED on the operator panel. The LED flashes until the
library is in Auto mode and then stays lit.
Note: If the high availability model is installed, the output facility still uses cells in
the control unit. The cells in the service bays are not available to the library.
Removing Ejected Cartridges from the Convenience Input⁄Output
Station Feature
1. Observe the Output mode LED on the operator panel. If the LED is lit, the
Convenience Input⁄Output Station has ejected cartridges.
2. Open the Convenience Input⁄Output Station door and remove all the cartridges.
3. Close the Convenience Input⁄Output Station door.
Note: The Convenience Input⁄Output Station receives ejected cartridges of all
types. A mixture of CST, ECCST, and HPCT (I, E, and J-types) should be
expected and no order relation exists. J-type cartridges may be any of the
following:
v
Newly-created Exported Stacked Volumes from the Export-Hold category
82
Magstar 3494 Tape Library Operator Guide
|
|
|
|
|
Содержание Tape Library Magstar 3494
Страница 1: ...Magstar 3494 Tape Library Operator Guide GA32 0280 09 IBM...
Страница 2: ......
Страница 3: ...Magstar 3494 Tape Library Operator Guide GA32 0280 09 IBM...
Страница 20: ...xviii Magstar 3494 Tape Library Operator Guide...
Страница 22: ...xx Magstar 3494 Tape Library Operator Guide...
Страница 27: ...A 0 6 C 0 0 4 1 Figure 2 Control Unit Frame Functional Components 3490E Front View Chapter 1 Introduction 5...
Страница 52: ...30 Magstar 3494 Tape Library Operator Guide...
Страница 62: ...40 Magstar 3494 Tape Library Operator Guide...
Страница 84: ...62 Magstar 3494 Tape Library Operator Guide...
Страница 106: ...84 Magstar 3494 Tape Library Operator Guide...
Страница 280: ...258 Magstar 3494 Tape Library Operator Guide...
Страница 326: ...304 Magstar 3494 Tape Library Operator Guide...
Страница 358: ...336 Magstar 3494 Tape Library Operator Guide...
Страница 374: ...352 Magstar 3494 Tape Library Operator Guide...
Страница 377: ......
Страница 378: ...IBMR Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber GA32 0280 09...