Important:
To ensure that any of your ServeRAID 10i, 10is, or 10M adapters
function properly on UEFI-based servers, make sure that the adapter firmware level
is updated to at least 11.xx-XXX, and the supporting drivers.
Attention:
Some cluster solutions require specific code levels or coordinated code
updates. If the device is part of a cluster solution, verify that the latest level of code
is supported for the cluster solution before you update the code.
To install the optional ServeRAID-MR10is SAS/SATA adapter, complete the
following steps:
1. Read the safety information beginning on page vii, and “Installation guidelines”
on page 141.
2. Touch the static-protective package containing the ServeRAID-MR10is adapter
to any unpainted metal surface on the server. Then, remove the
ServeRAID-MR10is adapter from the package.
3. If the battery pack (battery carrier and battery) did not come installed on the
ServeRAID adapter, install the battery pack.
a. Align the battery carrier pins and the connector for the battery carrier with
the pin holes and connector on the ServeRAID adapter; then, lower the
battery carrier onto the ServeRAID adapter.
Battery
Battery
carrier
ServeRAID
adapter
Connector
for battery
carrier
Hard disk
drive cable
connector 0-3
Hard disk
drive cable
connector 4-7
b. Press the battery carrier into the connector on the ServeRAID adapter until
it is firmly connected.
c. Secure the battery carrier to the ServeRAID adapter with the screws that
came with the battery pack.
4. Turn the ServeRAID-MR10is adapter so that the ServeRAID-MR10is adapter
keys align correctly with the connector.
Attention:
Incomplete insertion might cause damage to the system board or
the ServeRAID-MR10is adapter.
178
System x3200 M3 Types 7327 and 7328: Problem Determination and Service Guide
Содержание System x3200 M3
Страница 1: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 20: ...xviii System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 42: ...22 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 160: ...140 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 240: ...220 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 264: ...244 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 280: ...260 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 281: ......
Страница 282: ...Part Number 90Y5683 Printed in USA 1P P N 90Y5683...