Table 5. DSA Preboot messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3200 M3 Types 7327 and 7328,” on page 133 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained
service technician.
v
Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical information, hints, tips,
and new device drivers or to submit a request for information.
Message
number
Component
Test
State
Description
Action
215-903-xxx
Optical Drive
v
Verify Media
Installed
v
Read/ Write
Test
v
Self-Test
Messages and
actions apply to
all three tests.
Aborted
Could not access
the drive.
1. Insert a CD/DVD into the drive or try
a new media, and wait for 15
seconds.
2. Run the test again.
3. Check the drive cabling at both ends
for loose or broken connections or
damage to the cable. Replace the
cable if it is damaged.
4. Run the test again.
5. Make sure that the DSA code is at
the latest level. For the latest level of
DSA code, go to
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
6. Run the test again.
7. For additional troubleshooting
information, go to
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
8. Run the test again.
9. Replace the CD/DVD drive.
10. If the failure remains, go to the IBM
Web site for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
215-904-xxx
Optical Drive
v
Verify Media
Installed
v
Read/ Write
Test
v
Self-Test
Messages and
actions apply to
all three tests.
Failed
A read error
occurred.
1. Insert a CD/DVD into the drive or try
a new media, and wait for 15
seconds.
2. Run the test again.
3. Check the drive cabling at both ends
for loose or broken connections or
damage to the cable. Replace the
cable if it is damaged.
4. Run the test again.
5. For additional troubleshooting
information, go to
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
6. Run the test again.
7. Replace the CD/DVD drive.
8. If the failure remains, go to the IBM
Web site for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
118
System x3200 M3 Types 7327 and 7328: Problem Determination and Service Guide
Содержание System x3200 M3
Страница 1: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 20: ...xviii System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 42: ...22 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 160: ...140 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 240: ...220 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 264: ...244 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 280: ...260 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 281: ......
Страница 282: ...Part Number 90Y5683 Printed in USA 1P P N 90Y5683...