Table 5. DSA Preboot messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3200 M3 Types 7327 and 7328,” on page 133 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained
service technician.
v
Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical information, hints, tips,
and new device drivers or to submit a request for information.
Message
number
Component
Test
State
Description
Action
166-819-xxx
IMM
IMM I2C Test
Aborted
IMM I2C test
stopped: a
command response
could not be
provided; the SDR
repository is in
update mode.
1. Turn off the system and disconnect it
from the power source. You must
disconnect the system from ac power
to reset the IMM.
2. After 45 seconds, reconnect the
system to the power source and turn
on the system.
3. Run the test again.
4. Make sure that the DSA code is at
the latest level. For the latest level of
DSA code, go to
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
5. Make sure that the IMM firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in
the Firmware/VPD section for this
component. For more information, see
“Updating the firmware” on page 221.
6. Run the test again.
7. If the failure remains, go to the IBM
Web site for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
166-820-xxx
IMM
IMM I2C Test
Aborted
IMM I2C test
stopped: a
command response
could not be
provided; the
device is in
firmware update
mode.
1. Turn off the system and disconnect it
from the power source. You must
disconnect the system from ac power
to reset the IMM.
2. After 45 seconds, reconnect the
system to the power source and turn
on the system.
3. Run the test again.
4. Make sure that the DSA code and
IMM firmware are at the latest level.
5. Make sure that the IMM firmware is at
the latest level. The installed firmware
level is shown in the DSA event log in
the Firmware/VPD section for this
component. For more information, see
“Updating the firmware” on page 221.
6. Run the test again.
7. If the failure remains, go to the IBM
Web site for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
96
System x3200 M3 Types 7327 and 7328: Problem Determination and Service Guide
Содержание System x3200 M3
Страница 1: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 20: ...xviii System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 42: ...22 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 160: ...140 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 240: ...220 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 264: ...244 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 280: ...260 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 281: ......
Страница 282: ...Part Number 90Y5683 Printed in USA 1P P N 90Y5683...