Removing an optional ServeRAID-MR10i SAS/SATA controller
To remove a ServeRAID-MR10i SAS/SATA adapter, complete the following steps:
1. Read the safety information beginning on page vii, and “Installation guidelines”
on page 141.
2. Turn off the server and peripheral devices, and disconnect the power cords and
all external cables. Remove the side cover (see “Removing the side cover” on
page 145).
3. Rotate the rear adapter-retention bracket to the open (unlocked) position.
4. Disconnect any cables connected to the adapter.
Attention:
To avoid breaking the retaining clips or damaging the
ServeRAID-MR10i adapter connector, open and close the clips gently.
5. Carefully grasp the end of the ServeRAID adapter and pull it out of the
connector.
6. If you are instructed to return the adapter, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
Installing an optional ServeRAID-MR10i SAS/SATA controller
The optional IBM ServeRAID-MR10i SAS/SATA controller can be installed in either
PCI slot 1 or slot 2 on the system board. The ServeRAID-MR10i adapter is
supported on hot-swap server models only. The IBM ServeRAID-MR10i SAS/SATA
adapter enables integrated RAID levels 0, 1, 5, 6, and 10 support capability on
hot-swap hard disk drives. For configuration information, see the documentation on
the ServeRAID CD that comes with the adapter.
Important:
To ensure that any of your ServeRAID 10i, 10is, or 10M adapters
function properly on UEFI-based servers, make sure that the adapter firmware level
is updated to at least 11.xx-XXX, and the supporting drivers.
Attention:
Some cluster solutions require specific code levels or coordinated code
updates. If the device is part of a cluster solution, verify that the latest level of code
is supported for the cluster solution before you update the code.
To install a ServeRAID-MR10i adapter, complete the following steps:
1. Read the safety information beginning on page vii, and “Installation guidelines”
on page 141.
2. Touch the static-protective package containing the ServeRAID-MR10i adapter to
any unpainted metal surface on the server. Then, remove the ServeRAID-MR10i
adapter from the package.
3. If the battery pack (battery carrier and battery) did not come installed on the
ServeRAID adapter, install the battery pack.
a. Align the battery carrier pins and the connector for the battery carrier with
the pin holes and connector on the ServeRAID adapter; then, lower the
battery carrier onto the ServeRAID adapter.
Chapter 5. Removing and replacing server components
175
Содержание System x3200 M3
Страница 1: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 20: ...xviii System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 42: ...22 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 160: ...140 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 240: ...220 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 264: ...244 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 280: ...260 System x3200 M3 Types 7327 and 7328 Problem Determination and Service Guide...
Страница 281: ......