Table 6. IMM2 error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f0323-2101xxxx
Power cycle of system
initiated by IPMI
Watchdog.
Info
A power cycle by
watchdog has
been detected.
No action; information only.
806f0823-2101xxxx
Watchdog Timer
interrupt occurred for
IPMI Watchdog.
Info
A watchdog timer
interrupt has been
detected.
No action; information only.
806f0109-1301xxxx
Host power has been
power cycled.
Info
A power unit that
has been power
cycled has been
detected.
No action; information only.
806f0009-1301xxxx
Host Power has been
turned off.
Info
A power unit has
been disabled.
No action; information only.
80030012-2301xxxx Sensor OS RealTime
Mod has deasserted.
Info
An implementation
has detected a
sensor has
deasserted.
No action; information only.
80030006-2101xxxx Sensor Sig Verify Fail
has deasserted.
Info
An implementation
has detected a
sensor has
deasserted.
No action; information only.
80070202-0701xxxx Sensor Planar Fault
has transitioned to
critical from a less
severe state.
Error
A sensor has
changed to Critical
state from a less
severe state.
1. Check the system-event log.
2. Check for an error LED on the
system board.
3. Replace any failing device.
4. Check for a server firmware
update.
Important:
Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code
is supported for the cluster solution
before you update the code.
5. (Trained technician only) Replace
the system board (“Removing the
system board” on page 258 and
“Installing the system board” on
page 261).
806f0013-1701xxxx
A front panel NMI has
occurred on system
%1.
(%1 =
CIM_ComputerSystem.
ElementName)
Error
An operator
information panel
NMI/diagnostic
interrupt has
occurred.
1. Check the device driver.
2. Reinstall the device driver.
3. Update all device drivers to the
latest level.
4. Update the firmware (UEFI and
IMM2) (see “Updating the
firmware” on page 267).
60
IBM System x3100 M4 Type 2582: Problem Determination and Service Guide
Содержание System x3100 M4
Страница 1: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 24: ...4 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 42: ...22 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 170: ...150 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 182: ...162 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 238: ...Cage release latches 10 Remove the backplate 218 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 286: ...266 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 316: ...296 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 324: ...304 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 331: ......
Страница 332: ...Part Number 00V9701 Printed in USA 1P P N 00V9701...