Table 6. IMM2 error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
80010204-1d01xxxx Numeric sensor Fan A
Tach going low (lower
critical) has asserted.
Error
A lower critical
sensor going low
has asserted.
1. Reseat the failing fan, which is
indicated by a lit LED near the fan
connector on the system board.
2. Replace the failing fan (see
“Removing the rear system fan” on
page 211) and “Installing the rear
system fan” on page 213).
80070204-0a01xxxx
80070204-0a02xxxx
Sensor PS
n
Fan Fault
has transitioned to
critical from a less
severe state. (
n
=
power supply number)
Error
An implementation
has detected a
sensor transitioned
to critical from less
severe.
1. Make sure that there are no
obstructions, such as bundled
cables, to the airflow from the
power-supply fan.
2. Replace power supply
n
.
80010701-0701xxxx Numeric sensor
Ambient Temp going
high (upper non-critical)
has asserted.
Warning
An upper
non-critical sensor
going high has
asserted.
1. Reduce the ambient temperature.
2. Check the server airflow. Make
sure that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
80010901-0701xxxx Numeric sensor
Ambient Temp going
high (upper critical) has
asserted.
Error
An upper critical
sensor going high
has asserted
1. Reduce the ambient temperature.
2. Check the server airflow. Make
sure that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
80010b01-0701xxxx Numeric sensor
Ambient Temp going
high (upper
non-recoverable) has
asserted.
Error
An upper
non-recoverable
sensor going high
has asserted
1. Reduce the ambient temperature.
2. Check the server airflow. Make
sure that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
806f0125-1d01xxxx
Fan detected as
absent.
Info
An implementation
has detected a
managed element
is absent.
No action; information only.
80070201-2001xxxx
80070201-2002xxxx
80070201-2003xxxx
80070201-2004xxxx
Sensor DIMM
n
Temp
has transitioned to
critical from a less
severe state. (
n
=
DIMM number)
Error
A sensor has
transitioned to
critical from less
severe.
1. Check DIMM
n
error LED.
2. Replace DIMM
n
.
(
n
= DIMM number)
Power messages
806f0008-0a01xxxx
806f0008-0a02xxxx
The Power Supply
(Power Supply
n
)
presence has been
added to container. (
n
=
power supply number)
Info
Power supply
n
has been added.
(
n
= power supply
number)
No action; information only.
40
IBM System x3100 M4 Type 2582: Problem Determination and Service Guide
Содержание System x3100 M4
Страница 1: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 24: ...4 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 42: ...22 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 170: ...150 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 182: ...162 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 238: ...Cage release latches 10 Remove the backplate 218 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 286: ...266 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 316: ...296 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 324: ...304 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 331: ......
Страница 332: ...Part Number 00V9701 Printed in USA 1P P N 00V9701...