Table 6. IMM2 error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
80070201-0301xxxx Sensor CPU OverTemp
has transitioned to
critical from a less
severe state.
Error
A sensor has
changed to critical
state from a less
severe state.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow (front
and rear of the server), that the air
baffles are in place and correctly
installed, and that the server cover
is installed and completely closed.
2. Check the ambient temperature.
You must be operating within the
specifications (see “Features and
specifications” on page 7 for more
information).
3. Make sure that the heat sink for
microprocessor is installed
correctly.
4. (Trained technician only) Replace
microprocessor (see “Removing
the microprocessor and heat sink”
on page 250 and “Installing a
microprocessor and heat sink” on
page 254).
80070301-0301xxxx Sensor CPU OverTemp
has transitioned to
non-recoverable from a
less severe state.
Error
A sensor has
changed to
non-recoverable
state from a less
severe state.
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow (front
and rear of the server), that the air
baffles are in place and correctly
installed, and that the server cover
is installed and completely closed.
2. Check the ambient temperature.
You must be operating within the
specifications (see “Features and
specifications” on page 7 for more
information).
3. Make sure that the heat sink for
microprocessor is installed
correctly (see “Installing a
microprocessor and heat sink” on
page 254 for more information).
4. (Trained technician only) Replace
microprocessor (see “Removing
the microprocessor and heat sink”
on page 250 and “Installing a
microprocessor and heat sink” on
page 254).
Chapter 3. Diagnostics
45
Содержание System x3100 M4
Страница 1: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 24: ...4 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 42: ...22 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 170: ...150 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 182: ...162 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 238: ...Cage release latches 10 Remove the backplate 218 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 286: ...266 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 316: ...296 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 324: ...304 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 331: ......
Страница 332: ...Part Number 00V9701 Printed in USA 1P P N 00V9701...