Table 7. DSA Preboot messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3100 M4 Type 2582,” on page 151 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained
service technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints, tips, and
new device drivers or to submit a request for information.
Message
number
Component
Test
State
Description
Action
201-801-xxx
Memory
Memory Test
Aborted
Test canceled: the
system UEFI
programmed the
memory controller
with an invalid
CBAR address
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see “Updating the
firmware” on page 267.
4. Run the test again.
5. If the failure remains, go to the IBM
website for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
201-802-xxx
Memory
Memory Test
Aborted
Test canceled: the
end address in the
E820 function is
less than 16 MB.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that all DIMMs are
enabled in the Setup utility.
4. Make sure that the server firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see “Updating the
firmware” on page 267.
5. Run the test again.
6. If the failure remains, go to the IBM
website for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
126
IBM System x3100 M4 Type 2582: Problem Determination and Service Guide
Содержание System x3100 M4
Страница 1: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 24: ...4 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 42: ...22 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 170: ...150 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 182: ...162 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 238: ...Cage release latches 10 Remove the backplate 218 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 286: ...266 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 316: ...296 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 324: ...304 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 331: ......
Страница 332: ...Part Number 00V9701 Printed in USA 1P P N 00V9701...