Serial port problems
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing, System x3100 M4 Type 2582,” on page 151 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom
Action
The number of serial ports that
are identified by the operating
system is less than the number
of installed serial ports.
1. Make sure that:
v
Each port is assigned a unique address in the Setup utility program and
none of the serial ports is disabled.
v
The serial port adapter (if one is present) is seated correctly.
2. Reseat the serial port adapter.
3. Replace the serial port adapter.
A serial device does not work.
1. Make sure that:
v
The device is compatible with the server.
v
The serial port is enabled and is assigned a unique address.
v
The device is connected to the correct connector (see “Internal LEDs,
connectors, and jumpers” on page 17).
2. Reseat the following components:
a. Failing serial device
b. Serial cable
3. Replace the following components one at a time, in the order shown, restarting
the server each time:
a. Failing serial device
b. Serial cable
c. (Trained service technician only) System board
ServerGuide problems
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing, System x3100 M4 Type 2582,” on page 151 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom
Action
The
ServerGuide Setup and
Installation
CD will not start.
v
Make sure that the server supports the ServerGuide program and has a
startable (bootable) CD or DVD drive.
v
If the startup (boot) sequence settings have been changed, make sure that the
CD or DVD drive is first in the startup sequence.
v
If more than one CD or DVD drive is installed, make sure that only one drive is
set as the primary drive. Start the CD from the primary drive.
The ServeRAID program cannot
view all installed drives, or the
operating system cannot be
installed.
v
Make sure that there are no duplicate IRQ assignments.
v
Make sure that the hard disk drive is connected correctly.
The operating-system
installation program
continuously loops.
Make more space available on the hard disk.
Chapter 3. Diagnostics
91
Содержание System x3100 M4
Страница 1: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 24: ...4 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 42: ...22 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 170: ...150 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 182: ...162 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 238: ...Cage release latches 10 Remove the backplate 218 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 286: ...266 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 316: ...296 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 324: ...304 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Страница 331: ......
Страница 332: ...Part Number 00V9701 Printed in USA 1P P N 00V9701...