
Tray
ID
switch
The
Tray
ID
switch
settings
range
from
0
through
7,
and
unique
IDs
ranging
from
00
through
77
can
be
set.
Note:
For
controller
firmware
version
05.33.xx.xx,
both
host
and
expansion
ports
operate
at
2
Gbps
only.
For
controller
firmware
version
05.4x.xx.xx,
the
host
ports
can
operate
at
either
1
or
2
Gbps
(the
expansion
port
speed
is
still
locked
at
2
Gbps
only).
Diagnostics
To
diagnose
fibre
channel
problems,
use
FAStT
MSJ
(see
the
IBM
TotalStorage
DS4000
Problem
Determination
Guide
).
To
diagnose
problems
on
the
Type
1722
storage
system,
use
the
following
diagnostic
tools:
v
Storage
management
software
v
System
LEDs
Monitoring
status
through
software
Use
the
storage
management
software
to
monitor
the
status
of
the
storage
server.
Run
the
software
constantly,
and
check
it
frequently.
The
storage
management
software
provides
the
best
way
to
diagnose
and
repair
storage
server
failures.
The
software
can
help
you:
v
Determine
the
nature
of
the
failure
v
Locate
the
failed
component
v
Determine
the
recovery
procedures
to
repair
the
failure
Although
the
storage
server
has
fault
LEDs,
these
lights
do
not
necessarily
indicate
which
component
failed
or
needs
to
be
replaced,
or
which
type
of
recovery
procedure
you
must
perform.
In
some
cases
(such
as
loss
of
redundancy
in
various
components),
the
fault
LED
does
not
turn
on.
Only
the
storage
management
software
can
detect
the
failure.
For
example,
the
recovery
procedure
for
an
IBM
Predictive
Failure
Analysis
®
(PFA)
flag
(impending
drive
failure)
on
a
drive
varies
depending
on
the
drive
status
(hot
spare,
unassigned,
RAID
level,
current
logical
drive
status,
and
so
on).
Depending
on
the
circumstances,
a
PFA
flag
on
a
drive
can
indicate
a
high
risk
of
data
loss
(if
the
drive
is
in
a
RAID
0
volume)
or
a
minimal
risk
(if
the
drive
is
unassigned).
Only
the
storage
management
software
can
identify
the
risk
level
and
provide
the
necessary
recovery
procedures.
Note:
For
PFA
flags,
the
General-system-error
LED
and
Drive
fault
LEDs
do
not
turn
on,
so
checking
the
LEDs
will
not
notify
you
of
the
failure,
even
if
the
risk
of
data
loss
is
high.
Recovering
from
a
storage
server
failure
might
require
you
to
perform
procedures
other
than
replacing
the
component
(such
as
backing
up
the
logical
drive
or
failing
a
drive
before
you
remove
it).
The
storage
management
software
gives
these
procedures.
Attention:
You
might
lose
data
if
you
do
not
follow
the
software
recovery
procedures.
70
IBM
TotalStorage
DS4000:
Hardware
Maintenance
Manual
Содержание System Storage DS4000
Страница 1: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Страница 2: ......
Страница 3: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Страница 10: ...viii IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 16: ...xiv IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 30: ...2 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 38: ...10 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 44: ...16 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 48: ...20 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 88: ...60 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 120: ...92 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 138: ...110 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 146: ...118 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 178: ...150 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 183: ......
Страница 184: ...Printed in USA GC26 7702 00...