Using
the
diagnostic
hardware
The
DS4400
storage
server
comes
with
a
wrap-plug
adapter
and
LC
coupler.
The
wrap-plug
adapter
and
LC
coupler
are
used
to
identify
Fibre
channel
path
problems.
The
loopback
and
sendEcho
tests
are
described
in
the
IBM
TotalStorage
DS4000
Problem
Determination
Guide
.
Symptom-to-FRU
index
The
Symptom-to-FRU
index
(Table
41)
lists
symptoms
and
the
possible
causes.
The
most
likely
cause
is
listed
first.
The
problem
determination
(PD)
maps
found
in
the
IBM
TotalStorage
DS4000
Problem
Determination
Guide
provide
you
with
additional
diagnostic
aids.
Table
41.
Symptom-to-FRU
index
for
DS4400
storage
server
Problem
Action/FRU
Controller
LED
(front
cover)
is
on.
1.
Reseat
Controller
CRU.
2.
Place
Controller
online
using
DS4000
Storage
Manager
GUI.
3.
If
in
passive
mode,
check
Fibre
path/GBIC.
4.
Controller
CRU
Software
issued
a
controller
error
message.
1.
Check
Controller
Fan
2.
Controller
CRU
Software
errors
occur
when
attempting
to
access
controllers
or
drives.
1.
Check
appropriate
software
and
documentation
to
make
sure
the
system
is
set
up
correctly
and
the
proper
command
was
run.
2.
Power
to
the
Controller
3.
Interface
cables
4.
ID
settings
5.
Controller
6.
Drive
7.
Controller
backpanel
Fan
LED
(front
cover)
is
on.
1.
Power
supply
fan
CRU
2.
Controller
fan
CRU
Controller
and
Fan
fault
LEDs
(front
cover)
are
on.
1.
Check
both
Fan
and
Controller
CRUs
for
fault
LED
and
replace
faulty
CRU.
Fault-A
or
Fault-B
LED
(battery
CRU)
is
on.
1.
Battery
CRU
Full
Charge-A
or
Full
Charge-B
LED
(battery
CRU)
is
off.
1.
Power-on
Controller
and
allow
batteries
to
charge
for
24
hours
until
the
Full
Charge
LEDs
are
on.
2.
Battery
CRU
3.
Both
power
supplies
No
power
to
controller
(all
power
LEDs
off).
1.
Check
power
switches
and
power
cords.
2.
Power
supplies
Power
Supply
LED
is
off.
1.
Check
and
reseat
power
supply.
2.
Check
for
overheating.
Wait
ten
minutes
for
the
power
supply
CRU
to
cool
down.
3.
Power
supply
CRU
Chapter
10.
Type
1742
DS4400
Storage
Server
89
Содержание System Storage DS4000
Страница 1: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Страница 2: ......
Страница 3: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Страница 10: ...viii IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 16: ...xiv IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 30: ...2 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 38: ...10 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 44: ...16 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 48: ...20 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 88: ...60 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 120: ...92 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 138: ...110 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 146: ...118 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 178: ...150 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 183: ......
Страница 184: ...Printed in USA GC26 7702 00...