Note:
Throughout
this
chapter,
the
term
storage
server
refers
to
both
the
IBM
FAStT200
storage
server
(Model
3542-1RU)
and
the
IBM
FAStT200
HA
storage
server
(Model
3542-2RU).
Model-specific
information
is
noted
where
applicable.
Additional
service
information
This
section
provides
additional
service
information
about
the
IBM
FAStT200
storage
server.
Operating
specifications
Table
18
summarizes
the
operating
specifications
of
the
controller
unit.
Table
18.
Model
3542-2RU
storage
server
operating
specifications
Size
(with
front
panel
and
without
mounting
rails)
v
Depth:
57.5
cm
(22.6
in)
v
Height:
13.2
cm
(5.2
in)
v
Width:
48
cm
(18.9
in)
Weight
v
Standard
storage
server
as
shipped:
25.74
kg
(56.7
lb)
v
Typical
storage
server
fully
configured:
37.65
kg
(83
lb)
Electrical
input
v
Sine-wave
input
(50
to
60
Hz)
is
required
v
Input
voltage:
–
Low
range:
-
Minimum:
90
V
ac
-
Maximum:
136
V
ac
–
High
range:
-
Minimum:
198
V
ac
-
Maximum:
264
V
ac
–
Input
kilovolt-amperes
(kVA)
approximately:
-
Minimum
configuration:
0.06
kVA
-
Maximum
configuration:
0.37
kVA
Environment
v
Air
temperature:
–
Storage
server
on:
10°
to
35°
C
(50°
to
95°
F)
Altitude:
0
to
914
m
(3000
ft.)
–
Storage
server
on:
10°
to
32°
C
(50°
to
90°
F)
Altitude:
914
m
(3000
ft.)
to
2133
m
(7000
ft.)
v
Humidity:
–
8%
to
80%
Acoustical
noise
emissions
values
For
open
bay
(0
drives
installed)
and
typical
system
configurations
(8
hard
disk
drives
installed):
v
Sound
power
(idling):
–
6.3
bels
(open
bay)
–
6.5
bels
(typical)
v
Sound
power
(operating):
–
6.3
bels
(open
bay)
–
6.8
bels
(typical)
v
Sound
pressure
(idling):
–
47
dBA
(open
bay)
–
65
dBA
(typical)
v
Sound
pressure
(operating):
–
47
dBA
(open
bay)
–
68
dBA
(typical)
These
levels
are
measured
in
controlled
acoustical
environments
according
to
ISO
7779
and
are
reported
in
accordance
with
ISO
9296.
The
declared
sound
power
levels
indicate
an
upper
limit,
below
which
a
large
portion
of
machines
operate.
Sound
pressure
levels
in
your
location
might
exceed
the
average
1-meter
values
stated
because
of
room
reflections
and
other
nearby
noise.
Storage
server
components
The
following
sections
show
the
components
of
the
storage
server.
The
hot-swap
features
of
the
storage
server
enable
you
to
remove
and
replace
hard
disk
drives,
power
supplies,
RAID
controllers,
and
fans
without
turning
off
the
storage
server.
Therefore,
you
can
maintain
the
availability
of
your
system
while
a
hot-swap
device
is
removed,
installed,
or
replaced.
Front
view
Figure
24
on
page
37
shows
the
components
and
controls
on
the
front
of
the
server.
36
IBM
TotalStorage
DS4000:
Hardware
Maintenance
Manual
Содержание System Storage DS4000
Страница 1: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Страница 2: ......
Страница 3: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Страница 10: ...viii IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 16: ...xiv IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 30: ...2 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 38: ...10 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 44: ...16 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 48: ...20 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 88: ...60 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 120: ...92 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 138: ...110 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 146: ...118 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 178: ...150 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 183: ......
Страница 184: ...Printed in USA GC26 7702 00...