Router
>
version
SAN
Data
Gateway
Router
Version
0339.11
Built
Dec
13
1999,
15:14:14
VxWorks
(for
Pathlight
(i960RD))
version
5.3.1.
Kernel:
WIND
version
2.5.
value
=
26
=
0x1a
Router
>|
Diagnostics
The
diagnostic
suite
is
a
subset
of
the
manufacturing
test
program.
When
enabled,
the
diagnostic
suite
is
capable
of
performing
external
loopback
testing
of
all
major
hardware
interfaces
(SCSI,
fibre
channel,
and
Ethernet).
Toolkit
P/N
34L2606
(supplied
with
the
Router)
contains
the
necessary
loopback
plugs
to
run
the
Diagnostics.
It
includes
the
following
hardware:
v
Service
port
cable:
One
RS-232
null-modem
cable
with
9-pin
connectors
v
SCSI
loopback
cable:
One
short
wide-Ultra
cable
with
68-pin
connectors
v
Fibre
channel:
One
fibre
channel
short-wavelength
or
long-wavelenh
fiber-optic
loopback
plug
v
Ethernet:
One
10BASE-T
Ethernet
loopback
cable
v
Fuses:
Two
250
V,
4
A
time-lag
fuses
(type
F4AL)
Diagnostic
tests
To
verify
proper
operation
of
the
SDG
or
whenever
a
FRU
has
been
replaced,
a
complete
diagnostic
check
of
the
router
can
be
performed.
It
is
recommended
that
you
perform
these
tests
prior
to
returning
the
SDG
Router
to
the
customer.
Diagnostic
test
preparation
Perform
the
following
steps
to
verify
proper
operation
of
the
SDG
or
a
replaced
FRU:
1.
Attach
the
service
terminal
to
the
SDG
Router.
2.
Turn
on
the
SDG
Router
and
wait
until
it
has
finished
the
startup
cycle.
3.
From
the
service
terminal,
type
diagBoot
.
4.
Wait
until
the
SDG
Router
has
finished
the
startup
cycle.
The
Shell
prompt
should
be
diagmode>
.
5.
From
the
service
terminal,
type
showBox
.
6.
Verify
that
the
SDG
Router
is
configured
according
to
the
customer’s
requirements:
a.
If
all
installed
FRUs
are
shown,
go
to
″
Fibre
channel
tests
″
.
b.
If
all
installed
FRUs
are
not
shown,
see
Chapter
3
of
the
2108
Model
R03
Service
Guide
(MAP)
.
Fibre
channel
tests
Perform
the
following
steps
to
verify
proper
fibre
channel
operation:
1.
Attach
the
fibre
channel
loopback
plug
to
the
card
in
PMC
slot
1.
(You
can
also
use
the
plug
from
FAStT
MSJ).
Note:
This
test
works
only
if
the
card
is
an
ISP2200.
If
the
card
is
an
ISP
2100,
the
following
error
displays:
Card
in
slot
0
is
not
fibre
channel.
You
can
also
run
FAStT
MSJ
to
verify
if
the
SDG
Router
is
being
detected.
However,
you
cannot
run
the
diagnostics
(Loopback
and
Read/Write
Buffer
test)
on
the
SDG
Router.
2.
From
the
service
terminal,
type
fcSlotTest
1
Chapter
14.
IBM
Storage
Area
Network
Data
Gateway
Router
(2108-R03)
133
Содержание System Storage DS4000
Страница 1: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Страница 2: ......
Страница 3: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Страница 10: ...viii IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 16: ...xiv IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 30: ...2 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 38: ...10 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 44: ...16 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 48: ...20 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 88: ...60 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 120: ...92 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 138: ...110 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 146: ...118 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 178: ...150 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Страница 183: ......
Страница 184: ...Printed in USA GC26 7702 00...