Chapter 2. Removing and replacing parts
You can remove and replace field-replaceable units (FRUs) from the SAN Volume Controller, redundant
ac-power switch, and uninterruptible power supply.
Each FRU has its own removal procedure. Sometimes you can find that a step within a procedure might
refer you to a different remove/replace procedure. You might want to complete the new procedure before
you continue with the first procedure that you started.
Remove or replace parts only when you are directed to do so by the
IBM System Storage SAN Volume
Controller 2145 Troubleshooting Guide
. Start all problem determination and repair procedures with MAP
5000.
Enabling concurrent maintenance
To allow concurrent maintenance, SAN Volume Controllers must be configured in pairs.
While one SAN Volume Controller is being serviced, the other keeps the I/O group operational. With
concurrent maintenance, all field-replaceable units (FRUs) can be removed, replaced, and tested on one
SAN Volume Controller while the SAN and host systems are powered on and doing productive work.
Attention:
Do not remove the power from both SAN Volume Controllers unless the procedures instruct
you to do so.
Perform the following checks to verify that concurrent maintenance is enabled.
1.
Confirm that no hosts have dependencies on the node.
When shutting down a node that is part of a cluster or when deleting the node from a cluster, you
can use either the management GUI or a command-line interface (CLI) command. In the management
GUI, click
System Status
. Click the correct node and click
Manage
to display all the volumes that are
dependent on a node. You can also use the
node
parameter with the
svcinfo lsdependentvdisks
CLI
command to view dependent volumes.
If dependent volumes exist, determine if the volumes are being used. If the volumes are being used,
either restore the redundant configuration or suspend the host application. If a dependent quorum
disk is reported, repair the access to the quorum disk or modify the quorum disk configuration.
2.
Ensure that the host multipathing device drivers can fail over to the partner node.
Some host multipathing device drivers take a while to update after changes are made on the fabric.
Do not shut down a node or delete the node from a cluster if the partner node in the I/O group to
which the node belongs has not been online for more than 30 minutes.
If possible, check the status of the host multipathing device drivers before shutting down a node to
ensure that the device drivers can fail over to the partner node.
When shutting down the node, see MAP 5350 in the
IBM System Storage SAN Volume Controller 2145
Troubleshooting Guide
for a description of how to check for dependencies on the node during the
procedure to turn off the node.
When deleting a node from the cluster, see "Deleting a node from a cluster using the management GUI"
in the
IBM System Storage SAN Volume Controller 2145 Troubleshooting Guide
for a description of node
information to retain to avoid data corruption when adding the node back to the cluster, how to ensure
that the multipathing device driver does not rediscover any paths that are manually removed, and for
other considerations regarding dependent volumes.
© Copyright IBM Corp. 2003, 2010
19
Содержание SAN Volume Controller
Страница 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 Release 1 GC27 2226 03...
Страница 2: ......
Страница 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 Release 1 GC27 2226 03...
Страница 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 22: ...xx IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 26: ...xxiv IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 316: ...290 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 322: ...Taiwan Class A compliance statement 296 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 324: ...298 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 326: ...300 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 332: ...306 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 333: ......
Страница 334: ...Part Number 31P1173 Printed in USA GC27 2226 03 1P P N 31P1173...