3
Microprocessor
4
Heat sink installation label
8.
Replace the top cover. See “Replacing the top cover” on page 72.
9.
Place the node in the rack. See “Replacing the SAN Volume Controller in a rack” on page 48.
10.
Reconnect the power cable and any other cables that were removed.
11.
Turn on the node.
Replacing the SAN Volume Controller 2145-8F4 or SAN Volume Controller
2145-8F2 microprocessor
The SAN Volume Controller 2145-8F4 or SAN Volume Controller 2145-8F2 must always be fitted with
both microprocessors in order to function correctly.
The documented steps to replace the SAN Volume Controller 2145-8F4 or SAN Volume Controller
2145-8F2 microprocessor assume that you:
v
Removed all power from the node
v
Removed the node from the rack
v
Removed the top cover of the node
v
Removed the microprocessor that is being replaced
Perform the following steps to replace the SAN Volume Controller 2145-8F4 or SAN Volume Controller
2145-8F2 microprocessor:
1.
Touch the static-protective package that contains the new microprocessor to any
unpainted
metal
surface on the node.
2.
Remove the microprocessor from the package.
3.
Rotate the locking lever
3
from the closed position to the open position, as shown in Figure 261.
1
Microprocessor
2
Corner marks
3
Locking lever
4
Microprocessor socket
1
2
3
4
svc00127
Figure 261. Microprocessor locking lever in open position
Chapter 2. Removing and replacing parts
237
Содержание SAN Volume Controller
Страница 1: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 Release 1 GC27 2226 03...
Страница 2: ......
Страница 3: ...System Storage SAN Volume Controller Hardware Maintenance Guide Version 6 Release 1 GC27 2226 03...
Страница 14: ...xii IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 22: ...xx IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 26: ...xxiv IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 316: ...290 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 322: ...Taiwan Class A compliance statement 296 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 324: ...298 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 326: ...300 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 332: ...306 IBM SAN Volume Controller Hardware Maintenance Guide...
Страница 333: ......
Страница 334: ...Part Number 31P1173 Printed in USA GC27 2226 03 1P P N 31P1173...