System
alerts
System
alerts
are
generated
for
events
that
occur
as
a
result
of
system
errors.
If
the
Select
all
system
alerts
check
box
is
selected,
an
alert
can
be
sent
for
any
system
alert.
Notes:
a.
The
Select
all
system
alerts
check
box
is
not
available
on
all
servers.
b.
Hard
disk
drive
Predictive
Failure
Analysis
(PFA)
alerts
are
not
monitored.
Table
4.
System
remote
alerts
Alphanumeric
pager
code
Alphanumeric
recovery
code
Event
Action
20
70
POST
timeout
Generates
an
alert
if
an
enabled
POST
timeout
value
is
exceeded.
The
POST
timeout
value
is
configured
in
the
Server
Timeouts
area
on
the
System
page.
21
71
O/S
timeout
Generates
an
alert
if
an
enabled
operating
system
timeout
value
is
exceeded.
The
operating
system
timeout
value
is
configured
in
the
Server
Timeouts
area
on
the
System
page.
The
O/S
timeout
alert
must
be
checked
to
enable
remote
operating-system-failure
screen
capture.
22
72
Test
alert
Generates
an
alert
if
the
Generate
Test
Alert
button
is
clicked
on
the
Remote
Alert
Recipients
page.
23
73
Power
off
Generates
an
alert
if
the
server
is
turned
off.
24
74
Power
on
Generates
an
alert
if
the
server
is
turned
on.
25
75
Boot
failure
Generates
an
alert
if
an
error
occurs
that
prevents
the
server
from
starting.
26
76
Loader
timeout
Generates
an
alert
if
an
enabled
server
loader
timeout
value
is
exceeded.
The
system
loader
timeout
value
is
configured
in
the
Server
Timeouts
area
on
the
System
page.
27
77
PFA
notification
Generates
an
alert
if
a
PFA
notification
is
generated
by
the
server
hardware.
This
feature
is
available
only
on
servers
that
have
PFA-enabled
hardware.
28
-
29
Reserved
for
future
use.
38
88
Partition
configuration
Generates
an
alert
if
a
partition
configuration
notification
is
generated
by
the
server.
This
feature
is
available
only
on
servers
that
have
partitionable
hardware.
39
89
Event
log
Generates
an
alert
if
the
event
log
reaches
75%
or
100%
of
capacity,
or
if
the
log
is
cleared
(Refresh
2
or
later
firmware
only).
4.
Scroll
to
the
bottom
of
the
page
and
click
Save
.
Setting
local
events
Note:
For
the
Remote
Supervisor
Adapter
II
SlimLine,
the
setting
local
events
feature
is
available
only
when
using
LAN-based
alert
functionality.
Complete
the
following
steps
to
select
the
local
events
to
which
the
Remote
Supervisor
Adapter
II
will
respond:
Chapter
3.
Configuring
the
Remote
Supervisor
Adapter
II
29
Содержание Remote Supervisor Adapter II
Страница 1: ...Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 2: ......
Страница 3: ...Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 8: ...vi Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 12: ...4 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 76: ...68 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 86: ...78 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 120: ...112 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 126: ...118 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 131: ......
Страница 132: ...Part Number 43W7827 Printed in USA 1P P N 43W7827...