v
Nonmaskable
interrupt
3.
Enable
the
server
timeouts
that
correspond
to
the
events
that
you
want
the
Remote
Supervisor
Adapter
II
to
respond
to
automatically.
POST
watchdog
Use
the
POST
watchdog
field
to
specify
the
number
of
minutes
that
the
Remote
Supervisor
Adapter
II
will
wait
for
the
server
to
complete
a
power-on
self-test
(POST).
If
the
server
that
is
being
monitored
fails
to
complete
a
POST
within
the
specified
time,
the
Remote
Supervisor
Adapter
II
generates
a
POST
timeout
alert
and
automatically
restarts
the
server.
The
POST
watchdog
is
then
automatically
disabled
until
the
operating
system
is
shut
down
and
the
server
is
power
cycled
(or
until
the
operating
system
starts
and
the
software
is
successfully
loaded).
Note:
Power
cycling
means
that
the
server
is
turned
off
and
then
immediately
turned
on.
To
set
the
POST
timeout
value,
select
a
number
from
the
menu.
To
turn
off
this
option,
select
Disabled
.
Note:
If
the
POST
Time-out
check
box
is
selected
in
the
Remote
Alerts
area
of
the
Remote
Alerts
page,
the
Remote
Supervisor
Adapter
II
attempts
to
forward
the
alert
to
all
configured
remote
alert
recipients.
Also,
the
POST
watchdog
requires
a
specially
constructed
POST
routine
that
is
available
only
on
specific
IBM
servers.
If
this
routine
does
not
exist
on
your
server,
all
settings
in
this
field
are
ignored.
For
more
information
about
POST
routines,
see
the
documentation
that
comes
with
your
server.
O/S
watchdog
Use
the
O/S
watchdog
field
to
specify
the
number
of
minutes
between
checks
of
the
operating
system
by
the
Remote
Supervisor
Adapter
II.
If
the
operating
system
fails
to
respond
to
one
of
these
checks,
the
Remote
Supervisor
Adapter
II
generates
an
O/S
timeout
alert
and
restarts
the
server.
After
the
server
is
restarted,
the
O/S
watchdog
is
disabled
until
the
operating
system
is
shut
down
and
the
server
is
power
cycled.
To
set
the
O/S
watchdog
value,
select
a
time
interval
from
the
menu.
To
turn
off
this
watchdog,
select
Disabled
.
To
capture
operating-system-failure
screens,
you
must
enable
the
watchdog
in
the
O/S
watchdog
field
and
select
the
O/S
Time-out
check
box
in
the
Remote
Alerts
area
of
the
Alerts
page.
Notes:
a.
The
O/S
watchdog
feature
requires
that
the
Remote
Supervisor
Adapter
II
software
be
installed
on
the
server.
For
information
about
installing
this
software,
see
the
Remote
Supervisor
Adapter
II
Installation
Guide
.
b.
If
the
O/S
Time-out
check
box
is
selected
in
the
Remote
Alerts
area
of
the
Alerts
page,
the
Remote
Supervisor
Adapter
II
will
attempt
to
send
an
alert
to
all
configured
remote
alert
recipients.
Loader
watchdog
Use
the
Loader
watchdog
field
to
specify
the
number
of
minutes
that
the
Remote
Supervisor
Adapter
II
waits
between
the
completion
of
14
Remote
Supervisor
Adapter
II
SlimLine
and
Remote
Supervisor
Adapter
II:
User’s
Guide
Содержание Remote Supervisor Adapter II
Страница 1: ...Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 2: ......
Страница 3: ...Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 8: ...vi Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 12: ...4 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 76: ...68 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 86: ...78 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 120: ...112 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 126: ...118 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II User s Guide...
Страница 131: ......
Страница 132: ...Part Number 43W7827 Printed in USA 1P P N 43W7827...