Error Code Description
Action/
Possible Failing FRU
450D 25C0 Memory subsystem and attention handler
detected fault in system backplane
System backplane
Location: U1.18-P1
450D 25C1 Memory subsystem and attention handler
detected fault in 1.0 GHz clock card
Clock card
Location: U1.18-P1-X5
450D 25D9 Memory subsystem and attention handler
detected fault in L3 VPD card used with 1.1
GHz MCM and 1.3 GHz MCM
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
450D 25E7 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
450D 25E8 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
450D 25F1 Memory subsystem and attention handler
detected fault in L3 VPD card used with 1.3
GHz MCM
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
450D 25F9 Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
450D 269A Fault in L3 VPD card used with 1.5 GHz and
1.7 GHz MCMs
Go to “MAP 1548: Memory and Processor
Problem Isolation” on page 290.
450D 28B0 Memory subsystem and attention handler
detected fault in I/O subsystem PCI backplane
I/O subsystem PCI backplane at location
specified in error code
450D 28B1 Memory subsystem and attention handler
detected fault in I/O subsystem DASD
backplane
I/O subsystem DASD backplane at location
specified in error code
450D 302A Memory subsystem and attention handler
detected fault in 8 GB memory book (inner)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253 to isolate the failing
component.
450D 302B Memory subsystem and attention handler
detected fault in 8 GB memory book (outer)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253 to isolate the failing
component.
450D 302C Memory subsystem and attention handler
detected fault in 32 GB memory book (inner)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253 to isolate the failing
component.
450D 302D Memory subsystem and attention handler
detected fault in 32 GB memory book (outer)
Go to “MAP 1540: Problem Isolation
Procedures” on page 253 to isolate the failing
component.
450D 305A Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(inner)
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
450D 305B Memory subsystem and processor subsystem
tests detected fault in 8 GB memory book
(outer)
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
450D 305C Memory subsystem and attention handler
detected fault in 4 GB inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
450D 305D Memory subsystem and attention handler
detected fault in 4 GB outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
450D 305E Memory subsystem and attention handler
detected fault in 16 GB inner memory book
Go to “MAP 1544: Inner L3 Module Problem
Isolation” on page 282.
450D 305F Memory subsystem and attention handler
detected fault in 16 GB outer memory book
Go to “MAP 1545: Outer L3 Module Problem
Isolation” on page 284.
Chapter 5. Error Code to FRU Index
639
Содержание pSeries 670
Страница 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Страница 2: ......
Страница 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Страница 12: ...x Eserver pSeries 670 Service Guide...
Страница 16: ...xiv Eserver pSeries 670 Service Guide...
Страница 18: ...xvi Eserver pSeries 670 Service Guide...
Страница 256: ...Make sure all the green power good out LEDs of both I O subsystem DCAs are off 236 Eserver pSeries 670 Service Guide...
Страница 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Страница 718: ...698 Eserver pSeries 670 Service Guide...
Страница 828: ...number 8 Exit the menu completely before powering on the system 808 Eserver pSeries 670 Service Guide...
Страница 835: ...MCM Installation Shorts Test Step 3 See L3 Cache Modules on page 819 Chapter 9 Removal and Replacement Procedures 815...
Страница 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Страница 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Страница 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Страница 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Страница 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Страница 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Страница 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Страница 986: ...966 Eserver pSeries 670 Service Guide...
Страница 990: ...970 Eserver pSeries 670 Service Guide...
Страница 1005: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 985...
Страница 1018: ...998 Eserver pSeries 670 Service Guide...
Страница 1019: ...Appendix E Ground Path The ground path for the pSeries 670 is shown in the following figure 999...
Страница 1020: ...1000 Eserver pSeries 670 Service Guide...
Страница 1028: ...1008 Eserver pSeries 670 Service Guide...
Страница 1031: ......
Страница 1032: ...Printed in U S A July 2003 SA38 0615 03...