Error Code Description
Action/
Possible Failing FRU
4065 0C12 Display alter tests detected mismatch between
MCM 1 and VPD card
Plugging error with FRU kit
Location: U1.18-P1-C3 and U1.18-P1-H2.5
4065 0C13 Display alter tests detected mismatch between
MCM 3 and VPD card
Plugging error with FRU kit
Location: U1.18-P1-C2 and U1.18-P1-H2.6
4065 0CA5 Display alter tests detected invalid processor
subsystem configuration
Verify that MCMs, memory books, and L3
modules are correctly configured.
4065 0CA6 Display alter tests detected no usable main
storage
Reboot the system in slow mode to isolate the
failure.
4065 0CA9 Display alter tests detected configuration error
with processor memory
Reboot the system in slow mode to isolate the
failure.
4065 0D00 Display alter tests detected fault in L3 cache
module 0
L3 cache module 0 and L3 VPD card
Location: U1.18-P1-C6 and U1.18-P1-H2.1
4065 0D01 Display alter tests detected fault in L3 cache
module 1
L3 cache module 1 and L3 VPD card
Location: U1.18-P1-C7 and U1.18-P1-H2.1
4065 0D02 Display alter tests detected fault in L3 cache
module 2
L3 cache module 2 and L3 VPD card
Location: U1.18-P1-C11 and U1.18-P1-H2.1
4065 0D03 Display alter tests detected fault in L3 cache
module 3
L3 cache module 3 and L3 VPD card
Location: U1.18-P1-C10 and U1.18-P1-H2.1
4065 0D04 Display alter tests detected fault in L3 cache
module 4
L3 cache module 4 and L3 VPD card
Location: U1.18-P1-C8 and U1.18-P1-H2.1
4065 0D05 Display alter tests detected fault in L3 cache
module 5
L3 cache module 5 and L3 VPD card
Location: U1.18-P1-C20 and U1.18-P1-H2.1
4065 0D06 Display alter tests detected fault in L3 cache
module 6
L3 cache module 6 and L3 VPD card
Location: U1.18-P1-C16 and U1.18-P1-H2.1
4065 0D07 Display alter tests detected fault in L3 cache
module 7
L3 cache module 7 and L3 VPD card
Location: U1.18-P1-C12 and U1.18-P1-H2.1
4065 0D08 Display alter tests detected fault in L3 cache
module 8
L3 cache module 8 and L3 VPD card
Location: U1.18-P1-C19 and U1.18-P1-H2.1
4065 0D09 Display alter tests detected fault in L3 cache
module 9
L3 cache module 9 and L3 VPD card
Location: U1.18-P1-C18 and U1.18-P1-H2.1
4065 0D0A Display alter tests detected fault in L3 cache
module 10
L3 cache module 10 and L3 VPD card
Location: U1.18-P1-C14 and U1.18-P1-H2.1
4065 0D0B Display alter tests detected fault in L3 cache
module 11
L3 cache module 11 and L3 VPD card
Location: U1.18-P1-C15 and U1.18-P1-H2.1
4065 0D0C Display alter tests detected fault in L3 cache
module 12
L3 cache module 12 and L3 VPD card
Location: U1.18-P1-C17 and U1.18-P1-H2.1
4065 0D0D Display alter tests detected fault in L3 cache
module 13
L3 cache module 13 and L3 VPD card
Location: U1.18-P1-C5 and U1.18-P1-H2.1
4065 0D0E Display alter tests detected fault in L3 cache
module 14
L3 cache module 14 and L3 VPD card
Location: U1.18-P1-C9 and U1.18-P1-H2.1
4065 0D0F Display alter tests detected fault in L3 cache
module 15
L3 cache module 15 and L3 VPD card
Location: U1.18-P1-C13 and U1.18-P1-H2.1
466
Eserver
pSeries 670 Service Guide
Содержание pSeries 670
Страница 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Страница 2: ......
Страница 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Страница 12: ...x Eserver pSeries 670 Service Guide...
Страница 16: ...xiv Eserver pSeries 670 Service Guide...
Страница 18: ...xvi Eserver pSeries 670 Service Guide...
Страница 256: ...Make sure all the green power good out LEDs of both I O subsystem DCAs are off 236 Eserver pSeries 670 Service Guide...
Страница 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Страница 718: ...698 Eserver pSeries 670 Service Guide...
Страница 828: ...number 8 Exit the menu completely before powering on the system 808 Eserver pSeries 670 Service Guide...
Страница 835: ...MCM Installation Shorts Test Step 3 See L3 Cache Modules on page 819 Chapter 9 Removal and Replacement Procedures 815...
Страница 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Страница 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Страница 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Страница 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Страница 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Страница 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Страница 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Страница 986: ...966 Eserver pSeries 670 Service Guide...
Страница 990: ...970 Eserver pSeries 670 Service Guide...
Страница 1005: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 985...
Страница 1018: ...998 Eserver pSeries 670 Service Guide...
Страница 1019: ...Appendix E Ground Path The ground path for the pSeries 670 is shown in the following figure 999...
Страница 1020: ...1000 Eserver pSeries 670 Service Guide...
Страница 1028: ...1008 Eserver pSeries 670 Service Guide...
Страница 1031: ......