Step 1526-6
Set the breaker to the on (down) position. Wait 10 seconds after the LED on the IBF referenced in the
error code that brought you to this MAP comes on.
Does the circuit breaker remain on?
NO
Exchange the following FRUs one at a time:
v
The BPR that is connected to the IBF referenced in the error code that brought you to this MAP.
Follow all steps in the removal and replacement procedures for “Bulk Power Regulator (BPR)”
on page 783.
v
The IBF that is referenced in the error code that brought you to this MAP. Follow all steps in the
removal and replacement procedures for “Integrated Battery Feature (IBF)” on page 789.
v
The cable between the BPR and the IBF referenced in the error code that brought you to this
MAP.
After each FRU is exchanged, is the error code that sent you to this MAP still reported?
NO
The problem has been corrected. Go to
″
MAP 0410: Repair Checkout
″
in the
RS/6000 and
Eserver
pSeries Diagnostic Information for Multiple Bus Systems
.
YES
Replace the next FRU on the list. If all FRUs in the list have been replaced, call for
support.
YES
Go to
″
MAP 0410: Repair Checkout
″
in the
RS/6000 and
Eserver
pSeries Diagnostic Information
for Multiple Bus Systems
.
Step 1526-7
Is the error code that sent you to this MAP still reported?
NO
The problem has been corrected. Go to
″
MAP 0410: Repair Checkout
″
in the
RS/6000 and
Eserver
pSeries Diagnostic Information for Multiple Bus Systems
.
YES
Call for support.
Chapter 3. Maintenance Analysis Procedures
159
Содержание pSeries 670
Страница 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Страница 2: ......
Страница 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Страница 12: ...x Eserver pSeries 670 Service Guide...
Страница 16: ...xiv Eserver pSeries 670 Service Guide...
Страница 18: ...xvi Eserver pSeries 670 Service Guide...
Страница 256: ...Make sure all the green power good out LEDs of both I O subsystem DCAs are off 236 Eserver pSeries 670 Service Guide...
Страница 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Страница 718: ...698 Eserver pSeries 670 Service Guide...
Страница 828: ...number 8 Exit the menu completely before powering on the system 808 Eserver pSeries 670 Service Guide...
Страница 835: ...MCM Installation Shorts Test Step 3 See L3 Cache Modules on page 819 Chapter 9 Removal and Replacement Procedures 815...
Страница 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Страница 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Страница 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Страница 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Страница 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Страница 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Страница 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Страница 986: ...966 Eserver pSeries 670 Service Guide...
Страница 990: ...970 Eserver pSeries 670 Service Guide...
Страница 1005: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 985...
Страница 1018: ...998 Eserver pSeries 670 Service Guide...
Страница 1019: ...Appendix E Ground Path The ground path for the pSeries 670 is shown in the following figure 999...
Страница 1020: ...1000 Eserver pSeries 670 Service Guide...
Страница 1028: ...1008 Eserver pSeries 670 Service Guide...
Страница 1031: ......
Страница 1032: ...Printed in U S A July 2003 SA38 0615 03...