Step 1020-1
The following steps analyze a failure to load the diagnostic programs.
Note:
Be prepared to answer questions regarding the operator panel display and to perform certain
actions based on displayed POST indicators.
1. Run diagnostics on any partition. Find your symptom in the following table; then follow the instructions
given in the Action column.
If no fault is identified, continue to the next step.
2. Run diagnostics on the failing partition. Find your symptom in the following table; then follow the
instructions given in the Action column.
If no fault is identified, continue to the next step.
3. Power off the system. Refer to “Powering Off and Powering On the System” on page 779.
4. Load the standalone diagnostics in service mode to test the full system partition. Refer to Chapter 6,
“Using the Online and Standalone Diagnostics”, on page 699.
5. Wait until the diagnostics are loaded or the system appears to stop. If you receive an error code or if
the system stops before diagnostics are loaded, find your symptom in the following table; then follow
the instructions given in the Action column.
If no fault is identified, continue to the next step.
6. Run the standalone diagnostics on the entire system. Find your symptom in the following table; then
follow the instructions given in the Action column.
If no fault is identified, call service support for assistance.
Symptom
Action
One or more partitions do not boot.
1. Check service processor error log. If an error is
indicated, go to the “Entry MAP” on page 111.
2. Check the Serviceable Action Event (SAE) log, refer
to “Working With Serviceable Events” on page 7. If
there is a Service Action Event, perform the
recommended actions or go to the “Entry MAP” on
page 111.
The system stopped and a code is displayed on the
operator panel.
Go to the “Entry MAP” on page 111.
The system stops with a prompt to enter a password.
Enter the password. You cannot continue until a correct
password has been entered. When you have entered a
valid password, go to the beginning of this table and wait
for one of the other conditions to occur.
The diagnostic operating instructions are displayed.
Go to MAP 0020 in the
RS/6000 and
Eserver
pSeries
Diagnostic Information for Multiple Bus Systems
.
The power good LED does not come on or does not stay
on, or you have a power problem.
Go to “MAP 1520: Power” on page 144.
The system login prompt is displayed.
You may not have pressed the correct key or you may
not have pressed the key soon enough when you were to
trying to indicate a service mode IPL of the diagnostic
programs. If this is the case, start again at the beginning
of this step.
Note:
Perform the system shutdown procedure before
turning off the system.
If you are sure you pressed the correct key in a timely
manner, go to “Step 1020-2” on page 123.
The system does not respond when the password is
entered.
Go to “Step 1020-2” on page 123.
Chapter 3. Maintenance Analysis Procedures
121
Содержание pSeries 670
Страница 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Страница 2: ......
Страница 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Страница 12: ...x Eserver pSeries 670 Service Guide...
Страница 16: ...xiv Eserver pSeries 670 Service Guide...
Страница 18: ...xvi Eserver pSeries 670 Service Guide...
Страница 256: ...Make sure all the green power good out LEDs of both I O subsystem DCAs are off 236 Eserver pSeries 670 Service Guide...
Страница 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Страница 718: ...698 Eserver pSeries 670 Service Guide...
Страница 828: ...number 8 Exit the menu completely before powering on the system 808 Eserver pSeries 670 Service Guide...
Страница 835: ...MCM Installation Shorts Test Step 3 See L3 Cache Modules on page 819 Chapter 9 Removal and Replacement Procedures 815...
Страница 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Страница 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Страница 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Страница 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Страница 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Страница 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Страница 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Страница 986: ...966 Eserver pSeries 670 Service Guide...
Страница 990: ...970 Eserver pSeries 670 Service Guide...
Страница 1005: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 985...
Страница 1018: ...998 Eserver pSeries 670 Service Guide...
Страница 1019: ...Appendix E Ground Path The ground path for the pSeries 670 is shown in the following figure 999...
Страница 1020: ...1000 Eserver pSeries 670 Service Guide...
Страница 1028: ...1008 Eserver pSeries 670 Service Guide...
Страница 1031: ......
Страница 1032: ...Printed in U S A July 2003 SA38 0615 03...