Error Code Description
Action/
Possible Failing FRU
1023 BF06 Unable to resolve the chassis VPD in an I/O
subsystem
The chassis VPD in the I/O subsystem drawer
identified by the location code could not be
resolved. This may be an indication that more
than one FRU in the drawer was replaced during
a service action. If this is the case, reinstall the
original FRUs in the drawer, then replace the
FRUs one at a time.
If only one FRU was replaced and this error
code occurred, call service support.
1023 CD96 A power short has been detected in the DASD
subsystem in an I/O drawer.
Go to “MAP 1520: Power” on page 144.
1023 CDA6 A power short has been detected in the DASD
subsystem in an I/O drawer.
Go to “MAP 1520: Power” on page 144.
1023 CDB6 A power short has been detected in the DASD
subsystem in an I/O drawer.
Go to “MAP 1520: Power” on page 144.
1023 CDC6 A power short has been detected in the DASD
subsystem in an I/O drawer.
Go to “MAP 1520: Power” on page 144.
1023 F4x6 Hardware configuration does not support
N-mode power.
Call Service Support
1023 F516 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the fourth subsystem (with IBF,
location: U2.9.
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
1023 F526 An N+1 boundary (DCA or fan) has dropped to
N-mode status in the fourth I/O subsystem (with
IBF), location: U2.9.
This is normally an informational message. It
should be accompanied by other error codes
that more precisely indicate where the failure is.
Examine the service processor error log. If there
are no other power-related error codes (in the
time frame in which this code was generated) in
the service processor error log, the FRU
indicated with this error code, if any, should be
replaced.
1023 xx11 Fourth I/O subsystem moves to second rack
(with IBF), DCA-1
U2.9-V1
1023 xx13 Seeprom fault on DCA-1 in fourth I/O subsystem
(with IBF) in secondary rack
U2.9-V1
1023 xx15 Fourth I/O subsystem moves to second rack
(with IBF), DCA-1, cable fault
Go to “MAP 1520: Power” on page 144 with
these pairs of location codes:
1. U2.9-V1/Q1 and U1.35-P2-X2/Q5
2. U2.9-V1/Q2 and U1.35-P1-X2/Q5
1023 xx17 Problem with fan 1 and fan 3 in fourth I/O
subsystem (with IBF, moves to second rack)
1. DCA-1
Location U2.9–V1
2. Fan 1,
Location U2.9–F1
3. Fan 3,
Location U2.9–F3
402
Eserver
pSeries 670 Service Guide
Содержание pSeries 670
Страница 1: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Страница 2: ......
Страница 3: ...pSeries 670 Service Guide SA38 0615 03 ERserver...
Страница 12: ...x Eserver pSeries 670 Service Guide...
Страница 16: ...xiv Eserver pSeries 670 Service Guide...
Страница 18: ...xvi Eserver pSeries 670 Service Guide...
Страница 256: ...Make sure all the green power good out LEDs of both I O subsystem DCAs are off 236 Eserver pSeries 670 Service Guide...
Страница 324: ...Yes Go to Step 154A 14 on page 302 304 Eserver pSeries 670 Service Guide...
Страница 718: ...698 Eserver pSeries 670 Service Guide...
Страница 828: ...number 8 Exit the menu completely before powering on the system 808 Eserver pSeries 670 Service Guide...
Страница 835: ...MCM Installation Shorts Test Step 3 See L3 Cache Modules on page 819 Chapter 9 Removal and Replacement Procedures 815...
Страница 848: ...L3 Cache Shorts Test Step 4 828 Eserver pSeries 670 Service Guide...
Страница 849: ...L3 Cache Shorts Test Step 5 Chapter 9 Removal and Replacement Procedures 829...
Страница 851: ...L3 Cache Shorts Test Step 2 Chapter 9 Removal and Replacement Procedures 831...
Страница 853: ...L3 Cache Shorts Test Step 4 Chapter 9 Removal and Replacement Procedures 833...
Страница 854: ...L3 Cache Shorts Test Step 5 834 Eserver pSeries 670 Service Guide...
Страница 971: ...7040 Model 671 Media Subsystem 1 2 3 4 5 6 7 8 9 10 Chapter 10 Parts Information 951...
Страница 973: ...Power and SCSI Cables to the Media Subsystem 1 2 3 5 4 6 Chapter 10 Parts Information 953...
Страница 986: ...966 Eserver pSeries 670 Service Guide...
Страница 990: ...970 Eserver pSeries 670 Service Guide...
Страница 1005: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done Appendix D Modem Configurations 985...
Страница 1018: ...998 Eserver pSeries 670 Service Guide...
Страница 1019: ...Appendix E Ground Path The ground path for the pSeries 670 is shown in the following figure 999...
Страница 1020: ...1000 Eserver pSeries 670 Service Guide...
Страница 1028: ...1008 Eserver pSeries 670 Service Guide...
Страница 1031: ......
Страница 1032: ...Printed in U S A July 2003 SA38 0615 03...