Table 19. Sensor information, event description, and service action for the 8001-22C and 8005-22N (continued)
Sensor name (Sensor ID)
Event description
Service action
v
Mem Buf Temp 1 (0x5E)
v
Mem Buf Temp 2 (0x5F)
v
Mem Buf Temp 3 (0x60)
v
Mem Buf Temp 4 (0x61)
v
Transition to Critical from Less
Severe
v
Transition to Non-recoverable from
Less Severe
v
Transition to Critical from
Non-recoverable
Ensure that there are no air flow
obstructions at the front or at the rear
of the system. Ensure that the fans
are operating properly.
v
Lower Non-critical – going low
v
Lower Non-critical – going high
v
Lower Critical – going low
v
Lower Critical – going high
v
Lower Non-recoverable – going
low
v
Lower Non-recoverable – going
high
v
Upper Non-critical – going low
v
Upper Non-critical – going high
v
Upper Critical - going low
v
Upper Critical - going high
v
Upper Non-recoverable – going
low
v
Upper Non-recoverable – going
high
No service action is required.
v
P1M1-DIMMA Temp (0x66)
v
P1M1-DIMMB Temp (0x67)
v
P1M1-DIMMC Temp (0X68)
v
P1M1-DIMMD Temp (0x69)
v
P1M2-DIMMA Temp (0x6A)
v
P1M2-DIMMB Temp (0x6B)
v
P1M2-DIMMC Temp (0x6C)
v
P1M2-DIMMD Temp (0x6D)
v
P2M1-DIMMA Temp (0x6E)
v
P2M1-DIMMB Temp (0x6F)
v
P2M1-DIMMC Temp (0x70)
v
P2M1-DIMMD Temp (0x71)
v
P2M2-DIMMA Temp (0x72)
v
P2M2-DIMMB Temp (0x73)
v
P2M2-DIMMC Temp (0x74)
v
P2M2-DIMMD Temp (0x75)
v
Transition to Critical from Less
Severe
v
Transition to Non-recoverable from
Less Severe
v
Transition to Critical from
Non-recoverable
Ensure that there are no air flow
obstructions at the front or at the rear
of the system. Ensure that the fans
are operating properly.
v
Lower Non-critical – going low
v
Lower Non-critical – going high
v
Lower Critical – going low
v
Lower Critical – going high
v
Lower Non-recoverable – going
low
v
Lower Non-recoverable – going
high
v
Upper Non-critical – going low
v
Upper Non-critical – going high
v
Upper Critical - going low
v
Upper Critical - going high
v
Upper Non-recoverable – going
low
v
Upper Non-recoverable – going
high
No service action is required.
52
Problem analysis, system parts, and locations for the 8001-12C, 8001-22C, 8005-12N, and 8005-22N
Содержание Power System 8001-12C
Страница 2: ......
Страница 16: ...xiv Problem analysis system parts and locations for the 8001 12C 8001 22C 8005 12N and 8005 22N...
Страница 102: ...86 Problem analysis system parts and locations for the 8001 12C 8001 22C 8005 12N and 8005 22N...
Страница 111: ...System parts Figure 15 System parts Finding parts and locations 95...
Страница 116: ...100 Problem analysis system parts and locations for the 8001 12C 8001 22C 8005 12N and 8005 22N...
Страница 128: ...112 Problem analysis system parts and locations for the 8001 12C 8001 22C 8005 12N and 8005 22N...
Страница 129: ......
Страница 130: ...IBM...