The Advanced System Management Interface (ASMI) is the interface to the service processor that is
required to perform general and administrator-level service tasks, such as reading service processor
error logs, reading vital product data, setting up the service processor, controlling the system power,
and setting service processor network ports. The ASMI may also be referred to as the service
processor menus. The ASMI can be accessed through https. Perform the following steps:
a.
The control panel can be used in manual mode to display the service processor's IP addresses.
Refer to service functions to get control panel documentation in that case.
b.
Connect a client with a web browser directly to the service processor network ports you
previously noted. It could be something like the following URLs:
v
https://169.254.2.147
v
https://169.254.3.147
Note:
In some cases, the IP addresses might be different. For more information, see Function 30.
c.
If not already connected, connect all system power cables by plugging them into power outlets.
Note:
Do not start the system at this time.
d.
Log on to the ASMI with the admin User ID and admin default Password.
e.
Change the admin user ID Password and the general user ID Password when prompted.
f.
To configure network access perform the following steps:
1)
Click Network Configuration under the Network Services node.
2)
On the right pane, configure eth0 and eth1 network interfaces, select Static for the Type of IP
Address
field, and set and a Host name, an IP address, a Subnet mask.
29.
Restore system processor settings.
With the network connection now configured to use static IP address assignments, try to access the
service processor network ports.
Can you access the service network?
v
Yes
: Go to the next step.
v
No
: Go to step 34 on page 27.
30.
Access the ASMI.
The ASMI is the interface to the service processor that is required to perform general and
administrator-level service tasks, such as reading service processor error logs, reading vital product
data, setting up the service processor, and controlling the system power. The ASMI might also be
referred to as the service processor menus. To access the ASMI, see Accessing the Advanced System
Management Interface. After you have accessed the ASMI, continue with the next step.
31.
Set System Enclosure Type and Feature Code.
The enclosure serial number is a seven-digit number printed on a bar-coded label on the system
unit. When the system backplane is replaced, the seven-digit enclosure serial number and feature
code number needs to be manually inputted and stored in the new system backplane by using the
ASMI.
Note:
The feature code number for 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D
system backplane is 78AB-001.
Note:
To perform this operation, your authority level must be Authorized Service Provider (ID:
celogin).
To input the enclosure serial number and feature code, complete the following steps:
a.
On the ASMI Welcome pane, specify your user ID and password, and click Log in.
b.
In the navigation area, expand System Configuration > Program Vital Product Data.
c.
Select System Enclosures. In the right pane, the current system enclosures are displayed.
d.
On the system being serviced, record the enclosure serial number and feature code printed on the
bar-coded label on the system unit.
26
Power Systems: System backplane for the 8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D
Содержание Power 730 Express 8231-E2B
Страница 1: ...Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D IBM...
Страница 2: ......
Страница 3: ...Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D IBM...
Страница 14: ...2 Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D...
Страница 44: ...32 Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D...
Страница 110: ...98 Power Systems System backplane for the 8231 E2B 8231 E1C 8231 E1D 8231 E2C 8231 E2D or 8268 E1D...
Страница 111: ......
Страница 112: ...IBM Printed in USA...