POST Message
Description
176
The computer was tampered with. This indicates that the cover
has been removed and the chassis-intrusion detector has not been
cleared by entering the administrator password. Note that
chassis-intrusion can be detected only if the chassis-intrusion
detector feature is activated, which occurs when enhanced security
is enabled and an administrator password is set.
Action:
To reset the chassis-intrusion detector, you must enter the
administrator password.
186
Security hardware control logic error. The security data could
either not be read or written and the administrator password and
startup sequence are not reliable.
Action:
If your computer is in enhanced security mode, the
startup process will not continue. The system board must be
replaced.
187
A problem occurred with the administrator password and startup
(boot) sequence.
Action:
If enhanced security is not enabled, use the
Configuration/Setup Utility program to:
1. Clear the startup sequence (Start Options, Startup sequence).
2. Clear the administrator password. For instructions, see
“Deleting an Administrator Password” on page 46.
3. Reload the default settings (Load Default Settings).
4. Reset an administrator password. For instructions, see “Setting
and Changing an Administrator Password” on page 45.
For instructions on using the Configuration/Setup Utility program,
see “Using the Configuration/Setup Utility Program” on page 33.
190
The computer chassis-intrusion detector was cleared.
70
Using Your Personal Computer
Содержание PC 300PL Types 6862
Страница 1: ...Personal Computer Using Your Personal Computer PC 300PL...
Страница 2: ......
Страница 3: ...Personal Computer Using Your Personal Computer PC 300PL IBM...
Страница 12: ...x Using Your Personal Computer...
Страница 46: ...32 Using Your Personal Computer...
Страница 70: ...56 Using Your Personal Computer...
Страница 145: ......
Страница 146: ...IBM Part Number 06J0871 Printed in U S A July 1997 6J 871...