A15-12x
Description:
Sensor
detected
redundant
power
supply
failure.
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A15-13x
Description:
Sensor
detected
a
redundant
FRU
that
has
failed.
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A15-14x
Description:
Power
fault
due
to
unspecified
cause.
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A15-16x
Description:
Internal
power
supply
failure.
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A15-17x
Description:
Internal
redundant
power
supply
failure.
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A15-19x
Description:
Fan
failure.
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A15-20x
Description:
Non-critical
cooling
problem,
loss
of
redundant
fan.
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A15-21x
Description:
Over
temperature
condition.
Action:
Verify
the
following:
v
The
room
ambient
temperature
is
within
the
system
operating
environment.
v
There
is
unrestricted
air
flow
around
the
system.
v
All
system
covers
are
closed.
If
all
conditions
are
met,
then
use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A15-22x
Description:
Fan
failure
and
Over
temperature
condition.
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A15-23x
Description:
Non-critical
power
problem,
loss
of
redundant
power
supply.
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A15-24x
Description:
Power
Fault
specifically
due
to
internal
battery
failure.
Action:
Schedule
deferred
maintainence.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A15-50x
Description:
Recoverable
errors
on
resource
indicate
a
trend
toward
an
unrecoverable
error.
However,
the
resource
could
not
be
deconfigured
and
is
still
in
use.
The
system
is
operating
with
the
potential
for
an
unrecoverable
error.
Action:
If
repair
is
not
immediately
available,
reboot
and
the
resource
will
be
deconfigured.
Then
operations
can
continue
in
a
degraded
mode.
To
repair
use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A1D-00x
Description:
A
non-critical
error
has
been
detected.
Error
log
analysis
indicates
an
error
detected
by
the
Service
Processor,
but
the
failure
could
not
be
isolated.
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A1D-01x
Note:
Ensure
that
the
system
IPLROS
and
Service
Processor
are
at
the
latest
firmware
level
before
removing
any
parts
from
the
system.
Description:
A
non-critical
error
has
been
detected.
Time
Out
communication
response
from
Service
Processor
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A1D-02x
Description:
A
non-critical
error
has
been
detected,
an
I/O
(I2C)
general
bus
error.
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A1D-03x
Description:
A
non-critical
error
has
been
detected,
a
secondary
I/O
(I2C)
general
bus
error.
Action:
Schedule
deferred
maintenance.
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
Chapter
11.
SRNs
for
Linux
385
Содержание P 615 series
Страница 1: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Страница 2: ......
Страница 3: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Страница 12: ...x EserverpSeries 615 Service Guide...
Страница 16: ...xiv EserverpSeries 615 Service Guide...
Страница 18: ...xvi EserverpSeries 615 Service Guide...
Страница 58: ...38 EserverpSeries 615 Service Guide...
Страница 72: ...52 EserverpSeries 615 Service Guide...
Страница 150: ...130 EserverpSeries 615 Service Guide...
Страница 178: ...158 EserverpSeries 615 Service Guide...
Страница 284: ...264 EserverpSeries 615 Service Guide...
Страница 346: ...5 Start the system as described in Starting the System on page 283 326 EserverpSeries 615 Service Guide...
Страница 384: ...364 EserverpSeries 615 Service Guide...
Страница 385: ...Chapter 10 Parts Information This chapter contains parts information for the pSeries 615 Model 6C3 and Model 6E3 365...
Страница 386: ...System Parts 5 6 7 2 3 1 9 12 10 11 13 14 15 16 18 19 20 8 4 366 EserverpSeries 615 Service Guide...
Страница 388: ...Model 6C3Parts 5 5 7 6 6 2 3 1 4 368 EserverpSeries 615 Service Guide...
Страница 394: ...374 EserverpSeries 615 Service Guide...
Страница 418: ...398 EserverpSeries 615 Service Guide...
Страница 422: ...402 EserverpSeries 615 Service Guide...
Страница 438: ...418 EserverpSeries 615 Service Guide...
Страница 448: ...428 EserverpSeries 615 Service Guide...
Страница 452: ...432 EserverpSeries 615 Service Guide...
Страница 489: ......
Страница 490: ...Printed in U S A October 2003 SA38 0630 02...
Страница 491: ...Spine information pSeries 615 EserverpSeries 615 Service Guide SA38 0630 02...